5. Technical data

Mains voltage:
110 V ~ 60 Hz
Power input:
Idling speed:
11000 rpm
Max. wheel diameter:
Mounting spindle thread:
Protection class:
Weight:
Sound and vibration
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Additional information for electric power tools
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
n
order.
Service and clean the appliance regularly.
n
Adapt your working style to suit the appliance.
n
Do not overload the appliance.
n
Have the appliance serviced whenever
n
necessary.
Switch the appliance off when it is not in use.
n
Wear protective gloves.
n
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment's
construction and layout:
1. Lung damage if no suitable protective dust mask
is used.
2. Damage to hearing if no suitable ear protection is
used.
3. Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or
is not properly guided and maintained.
18
All manuals and user guides at all-guides.com

6. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
850 W
are identical to the mains data.
6.1 Fitting the additional handle (Fig. 2)
115 mm
The angle grinder must not be used without the
n
M14
additional handle (3).
II / ®
The additional handle can be secured in any of 2
n
positions (A, B).
1.7 kg
Tool side
Left (position A)
Right-handed users
Right (position B)
Left-handed users
6.2 Setting the guard (Fig. 3)
Switch off the tool. Pull the power plug.
n
Adjust the guard (4) to protect your hands so that
n
the material being ground is directed away from
your body.
The position of the guard (4) can be adjusted to
n
any specific working conditions. Undo the screw
(a) and turn the cover (4) into the required
position.
Ensure that the guard (4) correctly covers the
n
gear wheel casing.
Retighten the screw (a).
n
Ensure that the guard (4) is secure.
n
Take care that the safety device is secure.
Never use the angle grinder without the
guard.
6.3 TEST RUN FOR NEW GRINDING WHEELS
Allow the right-angle grinder to run in idle for at least
1 minute with the grinding or cutting wheel fitted in
place. Vibrating wheels are to be replaced
immediately.
7. Operation
7.1 Switch (Fig. 4)
The angle grinder comes with a safety switch which is
designed to prevent accidents. To switch on, push
the slide switch (a) to the right while at the same time
pushing the ON/OFF switch (2) forwards and
depressing. To switch off the angle grinder, depress
the button (2) at the back. The switch (2) will jump
back into its starting position.
Suitable for