Fuse blows
Fuse to small
Air in inlet hose
Inadequate supply of
mains water
Machine pulsating
Nozzle partially
blocked
Water filter blocked
hose kinked
Machin often
Pump/spray gun is
starts
leaking center.
and stops by itself
Pump/hoses or
Machine starts
accessory frozen no
, but no water
water supply water
comes out
filter blocked
Nozzle blocked
Change to an installation
higher than the amp.
consumption of the machine
.you may try without the
extension cord.
Allow machine to run with
open trigger until regular
working pressure resumes.
Check that the water supply
corresponds to specifications
required
NB! Avoid using long, thin
hoses (min.1/2")
Clean the nozzle
Clean the filter
Straighten out hose
Contact you nearest service
Wait for pump/hoses or ac-
cessory to thaw.
Connect inlet water.
Clean the filter
Clean the nozzle
21
User Manual