filters after every 50 hours of operation.
- clean the nozzle with tool provided. remove the lance from the gun,
remove any dirt from the nozzle hole and rinse.
TROUBLESHOOTING
Disconnect from the electrical power supply before carrying out user
maintenance or checking is correct functioning. To avoid unnecessary
disappointments, you should check the following before contacting the
service organization.
Symptom
Machine refuses
to start
Fluctuating
pressure
Machine stop
20
Induction Pressure Washer
Cause
Machine not plugged
in defective socket
fuse has blown defec-
tive extension cord
Pump sucking air
valves dirty worn out
or stuck pump seals
worn out.
Fuse has blown incor-
rect mains voltage
Thermal sensor acti-
vated nozzle partially
blocked
Recommended Action
Plug in machine try another
socket replace fuse. switch
off other machines.
Try without the extension
cord.
Check that hoses an d
connections are airtight.
Clean and replace or refer to
local distributor
Clean and replace or refer to
local distributor
Replace fuse. switch off other
machines.
Check that the mains voltage
corresponds to specification
on the model tag.
Leave the washer for 5 min-
utes to cool down. clean the
nozzle