Counter: It is possible to set the working time to 120 minutes. Turn the knob
clockwise and select the desired time.
OFF: The device has finished the countdown and turned off.
NOTE! Upon completion of treatment ventilate the room for 15 to 30 minutes. Do
not enter the room for at least 2 hours after completion of the ozone treatment.
NOTE! Use the device only in empty rooms! Ozone is an irritant gas, it may cause
damage to biological membranes through radical reactions with their constituents.
If the characteristic ozone smell is still present in the room which was treated with
ozone, first make sure that the device is switched off then leave the room and/or
ventilate it.
CAUTION! Do not look directly at the blue light produced by lamps.
3.4.
Cleaning and maintenance
a) Always unplug the device before cleaning it.
b) Use only non-corrosive cleaners to clean the surface.
c)
Store the unit in a dry, cool place, free from moisture and direct exposure to
sunlight.
d) Do not spray the device with a water jet or submerge it in water.
e) Do not allow water to get inside the device through vents in the housing of the
device.
f)
The device must be regularly inspected to check its technical efficiency and
spot any damage.