Error indicators
The casting machine is fitted with a fault monitoring system. The following errors can cause faults.
Fault
Red ERROR indicator lights
up, audible signal sounds
If faults cannot be remedied using this troubleshooting chart, call your service technician your dealer's
customer services directly.
TECHNICAL DATA
Mains voltage
Mains frequency
Max. power consumption
Average power consumption
Electric shock protection class
Starting torque
Max. weight of metal for melting
Max. melting temperature
Water requirement
Operational room temperature
Storage temperature
Relative ambient humidity
Dimensions (Width x Height x Depth)
Weight
Cause
Overheating of the machine
due to poor air circulation
Water circulation is cut off
The casting machine has
overheated as a result of
too many casting cycles
230 V
50/60 Hz
2,4 kVA
1,5 kVA
1
0...21 Nm
100 g
1,750 ºC
1 litre per min
15-40 ºC
5-40 ºC
max 70 %
560 x 400 x 600 mm
65 kg
Remedy
Allow a minimum gap of 20 cm between the
casting machine and any surrounding units or
walls.
Check water connections and turn on the
stopcock.
Integrated heat safety device automatically
cuts off the heating cycle for 5 minutes.