Herunterladen Diese Seite drucken

HOMCOM 800-190V70 Gebrauchsanweisung Seite 14

Werbung

1)There is no water
coming into the
interior of
dishwasher
2) The abnormality of
drain valve leads to
too much water
come into interior of
dishwasher in the
1st phase, while too
less water in the 3rd
phase, but the water
flow is normal
E1 error appears
during water comes
into the interior of
dishwasher
E1
E1 appears at 3rd
phase, and the water
flow is very little
Temperature sensor
is broken
E2
1) Change the
component-drain
valve
2)User can fill up
water tank with
water, long press
Dry key to activate
Draining process, it
lasts 4 minutes.
And if after several
tries, the problem is
still not solve, it
needs to change
the component-
drain valve
Change the
component- flow
meter
Chang the component-
submersible pump
Change the
component-
temperature sensor
14

Werbung

loading

Diese Anleitung auch für:

800-190v90800-190v70wt