TM63 Operating Instructions Digital Contact Thermometer
TECHNICAL DATA
Measuring range
Temperature range
Output
Analog output
Contact output
Power supply
20 mA output
10 V output
Signal characteristics
Accuracy
Long term stability
Response time
Swich-on time
Temperature coefficient
PT1000B
Temperature ranges
Medium temperature
Surrounding temperature
Storage temperature
Electrical protections
Short-circuit resistance
Reverse polarity protection
Electromagnetic compatibility
Wetted materials
Process connection
Surroundings
Protection type
Exemplary weight
TM63-A-11-305-00 (figure p. 1)
Nöding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: +49 40 67 58 51 – 0
Fax: +49 40 67 58 51 – 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-messtechnik.de
See table „ Measuring ranges"
others on request
4...20 mA, 2-wires
0...10 V, 3-wires
0...20 mA, 2-wires
DC PNP, max. 200 mA
10...30 V DC
16...30 V DC
≤ ± 0,3 % FS @ 25 °C +0,3 °C
Pt1000 Kl.B: + 0,005 °C x t
≤ ± 0,2 % FS / Y ear
200 ms - andere Werte auf Anfrage
< 1 s
≤ ± 0,02 % FS / Kelvin
-50...200 °C
-25...80 °C
-40...85 °C
Permanent
Protection against reverse polarity, but no function
Interference emissions and immunity acc. to EN 61326
Stainless steel 1.4404
IP 67
Approx. 300 g
ELECTRICAL CONNECTION
Connector M8x1 4-pole
brown
white
black
SP1
SP2
gray
blue
LOAD
1000
10V
EN
u
B
30V