INITIAL OPERATING
Mounting of the machine
The machine should be mounted with turning wheels
and rear axle with rear wheels. The turning wheels
can be mounted without opening the machine. Use
either a ring spanner or a small wheel spanner.
Mains supply
The machine is designed for 230V (220-240V) and
must not be connected to other voltages.
Gas connection
The mashine is designed for use of a 6/10 kg gas
bottle with a maximum height of 100 cm. Larger
bottles must not be used due to risk of overloading
the machine or the machine will overturn.
TECHNICAL DATA
Mains voltage
Consumption (duty cycle 60%)
Fuse
Maximum input current
Open circuit voltage (DC)
Welding current range
Duty cycle, 20 %
Duty cycle, 60 %
Duty cycle, 100 %
Voltage adjustment
Insulation class
1
Protection class
Dimensions (WxHxL)
Weight
1
This machine is designed for indoor operation and
meets the requirements of protection class IP21.
1. On
2. Overheating
3. Wire feed speed control
Rally MIG 160
230 V / 50 Hz
4. Main switch and switch for welding voltage
4.8 kVA
5. Connection of welding hose
T 13 A
21 A
6. Fuse
17.5 – 31.5 V
30 – 150 A
150 A
90 A
70 A
5
F
IP 21
230x550x665 mm
49 kg

CONTROL SWITCHES

3
4
Lights when the machine has been turned on.
Lights if the welding process is automatically
stopped due to overheating of the transformer.
The light extinguishes when the transformer
temperature has dropped to normal, and weld-
ing can continue.