Herunterladen Diese Seite drucken

Hilti TE 300-AVR 01 Bedienungsanleitung Seite 20

Vorschau ausblenden Andere Handbücher für TE 300-AVR 01:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Technical data
Breaker
When powered by a generator or transformer, the generator or transformer's power output must
be at least twice the rated input power shown on the rating plate of the power tool. The operating
voltage of the transformer or generator must always be within +5% and -15% of the rated voltage of
the power tool.
The information given applies to a rated voltage of 230 V. The data may vary in the event of deviations
from the rated voltage and for country-specific versions. Please refer to the power tool's rating plate
for details of its voltage, frequency, current and input power ratings.
Product generation
Weight in accordance with EPTA
procedure 01
Single impact energy in
accordance with EPTA
procedure 05/2009
Noise information and vibration values
The sound pressure and vibration values given in these instructions were measured in accordance
with a standardized test and can be used to compare one power tool with another. They can also be
used for a preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used
for different applications, with different accessory tools, or is poorly maintained, the data can vary.
This can significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is
switched off, or when it is running but not actually being used for a job. This can significantly reduce
exposure over the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration,
for example: maintaining the power tool and accessory tools, keeping the hands warm, organization
of work patterns.
Detailed information on the versions of the EN 62841 standards applied here is to be found in
the reproduction of the declaration of conformity
Noise emission values determined in accordance with EN 60745-2-6
Measured sound power level (L
Uncertainty for the sound power level (K
Sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration (vector sum of three directions), measured in accordance with EN 60745-2-6
Chiseling in concrete (a
Uncertainty (K)
14
TE 300­AVR
01
3.8 kg
3.3 J
)
WA
WA
)
pA
)
h, Cheq
133.
100 dB(A)
)
3 dB(A)
92 dB(A)
)
3 dB(A)
pA
11 m/s²
1.5 m/s²
401136
*401136*

Werbung

loading

Diese Anleitung auch für:

Te 300-avr