2.8.3.26 Parameter change (Function call Event: Effect )
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the corresponding effect's function activates (depending
on the effect type).
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
01111111 7F
Function call Effect Event
ADDRESS
00010010 12
function
0000ffff 0f
00000000 00
Release:0, Press:1
0ppppppp pp
DATA
00000000 00
Effect number (0:Effect1 - 3:Effect4)
0eeeeeee ee
End of exclusive
EOX
11110111 F7
function
Freeze Play button
0x00
Freeze Record button
0x01
• This does not activate when the effect type is different.
2.8.3.27 Parameter change
When scene memory sort is executed on the 01V96, the memory sort table will
be transmitted to Studio Manager.
Studio Manager will sort the memories according to this data.
If Studio Manager performs a scene memory sort, it will transmit this data to
the 01V96.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Library sort table
ADDRESS
00010011 13
Library type
0000ffff 0f
Data
DATA
0ddddddd ds
:
:
Data
0ddddddd de
End of exclusive
EOX
11110111 F7
8-7 conversion is performed on the data area in the same way as for bulk.
2.8.3.28 Parameter request
When the 01V96 receives this data, it will transmit Sort Table Data.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Library sort table
ADDRESS
00010011 13
Library type
0000ffff 0f
End of exclusive
EOX
11110111 F7
channel
0:Effect1-3:Effect4
0:Effect1-3:Effect4
(Sort Table)
(Sort Table)
MIDI-Datenformat
2.8.3.29 Parameter change
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the same processing that is executed when the key speci-
fied by Address is pressed (released).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Key remote
ADDRESS
00100000 20
Key address H
0kkkkkkk kk
Key address M
0kkkkkkk kk
Key address L
0kkkkkkk kk
Release:0, Press:1
DATA
0ppppppp pp
End of exclusive
EOX
11110111 F7
2.8.3.30 Parameter change
When transmission is enabled by receiving a Request of Remote meter, the spe-
cified meter information is transmitted every 50 msec for 10 seconds. When you
want to transmit meter information continuously, a Request must be transmit-
ted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified by
Address will be transmitted on the [Rx CH] channel at 50 msec intervals for a
duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Remote meter
ADDRESS
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1 H
DATA
0ddddddd dd
Data1 L
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
* Meter data uses the unmodified DECAY value of the DSP. The inter-
pretation of the data will depend on the parameter.