using an external CO₂ cylinder, the
instructions of the supplier shall be strictly
followed. The CO₂ cylinder should never
be laid down horizontally.
• If CO₂ escapes into the room, ventilate the
room, and leave it for some time to ensure
a sufficient supply of fresh air. Even the
total amount inside of a 425 g cylinder is
not sufficient to reach lifethreatening
concentrations in the air if it escapes.
• If you transport the unit, the CO₂ cylinder
shall be uninstalled.
• Do not use osmosis water or highly
filtered water in the system. It can lead to
problems in the level control.
• It is not permitted to operate Franke
Mythos Water Hub without a connect
filter.
If Franke Mythos Water Hub is connected
to a water supply with a water softener
and the water hardness is below 7 °dKH a
freshwater filter (Franke Clear Water
Connect filter) could be used instead of a
standard filter with decalcification (Franke
Pro M Connect filter).
Caution: Never use serrated tools in
order to avoid damage. Where necessary,
always use the appropriate tools for
tightening the coupling.
Always keep safety tags and notes on
the product in a legible condition. Replace
damaged safety tags and notes
immediately!
• At the installation location, Franke Mythos
Water Hub must be protected from
mechanical damage, heat and direct
sunlight, open flames and the danger of
frost.
• As a result of the ongoing improvement of
our products and/or systems, illustrations
in this document may differ from the
appliance as delivered.
• If available, you can download the latest
version of the manual via our website:
www.franke.com
Filter cartridge
The use of a Franke filter is mandatory
to protect the product against limescale
deposits. It is mandatory to change the filter
based on the water hardness table.
• After storage at a temperature of 0 °C, the
filter must first be stored for 24 hours at
room temperature before it is installed.
• The filter cartridge must not be opened or
damaged.
• The filter cartridge and the system must
be intensively flushed after a prolonged
standstill period and/or during
maintenance work (2 liters of flushing
water after 1 week standstill; 10 liters of
flushing water after 4 weeks' standstill).
The filter cartridge must be replaced if,
after commissioning, it has not been in
operation for 3 months.
Declaration of Conformity
The manufacturer declares that this device
with wireless radio functionality complies
with Directive 2014/53/EU.
The complete text of the EU declaration of
conformity is available at the following link
by searching for the product code:
https://www.franke.com/ en/product-
documentation/
This code can be found on the label located
inside the product.
Frequency bands
2.4 GHz
PSTI Statement of Compliance
The manufacturer declares that this product
is compliant with the applicable security
requirements in Schedule 1 of The Product
Security and Telecommunications
Infrastructure (Security Requirements for
Relevant Connectable Products)
7
Maximum transmitted
power
100 mW max.
EN