These operating instructions belong exclusively to the above-mentioned product. It contains important
information on the commissioning and handling of the luminaire. Therefore, please pay attention to these
operating instructions, even if you pass this product on to third parties. It is therefore important that you
keep these instructions in a safe place for future reference.
. Introduction
Dear customer, thank you for purchasing our product. You have purchased a product from LDBS, which has
been built according to the current state of the art. The luminaire meets the requirements of the applicable
European and national directives. In order to maintain the condition of the product and to ensure safe operation,
you as the user must observe these operating instructions!

. Safety instructions

In case of damage caused by non-observance of these operating instructions,
the warranty claim expires!
We do not assume any liability for consequential damages!
If the lamp is damaged, it is strictly forbidden to put it into operation.
Do not allow children to play unsupervised in the area of the luminaires or other electrical devices.
During operation, the LEDs become hot. The outer lamp housing also becomes warm.
Do not bring the luminaire into contact with extreme heat or open flame.
Do not modify or alter the entire product. Modifications to the luminaire will void the warranty.
The type plate must not be removed.
. Before installation/commissioning
The luminaire is designed for indoor/outdoor use.
This product is for lighting purposes only and may:
only be operated with a voltage of 230V ~50Hz in protection class II (two).
only be operated on normal or non-flammable surfaces.
not be exposed to strong mechanical stresses or heavy soiling.
The luminaire may only be operated outside the packaging.
Carefully remove the luminaire from its packaging.
Before operating the luminaire, make sure that it has not been damaged during transport. If any electrical
parts are damaged, do not operate the lamp.
Keep packaging material away from children and pets. Danger of suffocation!
. Installation/Commissioning
This product may only be installed by a qualified electrician.
Before installation, the building's connecting cables must be disconnected from the power supply and
secured against being switched on again. To do this, disconnect the corresponding circuit breaker of the
building installation.
Make sure that the substrate is suitable to support the weight of the luminaire permanently and reliably.
Place the luminaire with the back facing upwards in front of you, with the inscription "Press" facing you.
Press a narrow object into the hole, now you can remove the rear part of the luminaire counterclockwise.
Unscrew the cover of the cable gland. Guide the mains cable through the inlet in the luminaire (use the
seal!). Mark the drill holes and drill them. Then screw the back part of the luminaire to the ceiling.
Make sure that there is no cable in the area of the bayonet catch, you may have to shorten the cable. Use
the strain relief, the cable sheath should be removed after the strain relief so that the shortest way to the
terminals is possible. Strip approx. 10 mm of insulation from the brown and blue cables.
Connect the brown cable in terminal L of the screwless connector. Then connect the blue cable to terminal
N.
Check again that the connection is correct.
The sensor can detect movements even through thin walls and doors. The sensitivity can be adjusted with
DIP switches as described below.
Now put on the front part of the lamp, position it so that the inscription "Press" is approx. 10cm to the right
of the latching point and then turn the front part clockwise until it latches.
Switch on the circuit breaker of the house installation again.
LDBS Lichtdienst GmbH, Chemnitzer Straße 8, 14612 Falkensee, www.heitronic.de