Preset programmes:
Programme
1
Temperature setting
80 °C/180 °F
(°C/°F)
Airflow setting
4
Emissivity
0.95
d) LOC function
To avoid altering the chosen settings unin-
tentionally, the HG Scan PRO comes with the
Lockable Override Control Function (LOC).
Alarm function
HG Scan PRO comes with an alarm function
that is activated when the temperature meas-
ured exceeds or falls below the temperature
selected. The alarm is given in acoustic form by
an audio signal and in visual form by a blue and
red LED ring. The alarm is triggered when the
temperature measured exceeds or falls below
the temperature that is set.
Alarm function table
Variations from the temperature setpoint in °C
Alarm tolerance levels
Red LED ring & audio signal
Red LED ring
Green LED ring
Blue LED ring
-20 °C to -10 °C
Blue LED ring & audio signal
Variations from the temperature setpoint in °F
Alarm tolerance levels
Red LED ring & audio signal
Red LED ring
Green LED ring
-70 °F to -50 °F
Blue LED ring
Blue LED ring & audio signal
2
3
120 °C/250 °F
160 °C/320 °F
250 °C/480 °F
5
6
0.85
0.90
To find out how to set the LOC function,
please contact our Service Department on
05245-448-188.
A green LED ring shows that the temperature
measured by HG Scan PRO is equivalent
to the target value within the tolerance. The
acoustic audio signal can be deactivated. To
deactivate the audio signal, go to the section
on "Settings".
10 °C
20 °C
> 20 °C
> 40 °C
10 °C to 20 °C
20 °C to 40 °C
-10 °C to 10 °C
-20 °C to 20 °C
-40 °C to -20 °C
< -20 °C
< -40 °C
50 °F
70 °F
> 70 °F
> 100 °F
50 °F to 70 °F
70 °F to 100 °F
-50 °F to 50 °F
-70 °F to 70 °F
-100 °F to -70 °F
> -70 °F
> -100 °F
- 16 -
Emissivity
HG Scan PRO's emissivity can be selected to
4
obtain accurate measurement readings for dif-
ferent materials and surfaces (see table).
Surface
5
Car films
0.94
Wood
Rubber
Oil-based paints
Leather
Lacquers
Paper, card
Textiles
Plastic (PVC, PE, PP)
The emissivities shown in the emissivity table are approximations. Surface quality, geometry or
other parameters may influence the emissivity of the object being measured.
Please go to our website for a detailed overview:
www.steinel-professional.de/emissionswerte (German)
www.steinel-professional.de/emissivities (other languages)

Technical specifications

Operating voltage:
Response time:
Spectrum:
Emissivity:
Resolution:
Working distance:
IR measurement area:
Operating temperature:
Operating air humidity:
Storage temperature:
Storage air humidity:
Temperature measurement range:
Accuracy *:
Weight:
Dimensions:
*
Accuracy at an ambient temperature of approx. 25 °C and maintaining the optimum distance
from the object being measured.
The display shows the figures after the
decimal point. (tenths and hundredths)
e.g. 0.93 equates to 93.
Emissivity
0.90-0.95
0.80-0.90
0.85-0.95
0.95
0.75-0.85
0.80-0.95
0.75-0.95
0.90
0.85-0.95
HG Scan PRO 2620 E
HG Scan PRO2520 E
15V DC
500 ms
8-14 µm
0.10-0.99
10 °C / 10 °F
10 cm
10:1
0-50 °C / 32-122 °F
10 % - 90 % RH
-10-60 °C / 14-140 °F
< 80 % RH
0 °C - 300 °C (32 °F - 572 °F)
±2 °C / ±3.6 °F or ±5 % of the temperature measured
120 g
85 g
99 x 95 x 153 mm
88 x 56.5 x 77 mm