7. Cleaning and maintenance

• Turn off the device and disconnect it from the external power supply before each cleaning
• The device must not be cleaned under running water.
• Do not use aggressive cleaning agents.
• Clean the outside and inside of the device with a damp cloth, excluding the control panel and power section.
• Manual defrosting
During long-term operation, a layer of ice can appear inside. This can reduce its performance.
To defrost the device, disconnect it from the power supply, empty the cooling compartment and leave the door open. After ice has condensed, wipe off the remaining
water with a soft cloth. Do not use any hard or sharp tools.
• Replacing the fuse
CAUTION! Before replacing the fuse, turn the device off and disconnect it from the power supply.
1. Remove the fuse cover
2. Remove the fuse and replace it with a new one with the same technical parameters.
3. Reinstall the fuse cover.
Fuse specification
Current Rating
Voltage Drop
Cold Resistance
I2t
8. Troubleshooting
the most common faults
• Foodstuffs are frozen:
Change the cooling temperature to a higher one, the set temperature is too low.
• Drops of liquid appear around the refrigerator door:
Liquid drops appear due to the temperature difference between the device and its surroundings and are a normal phenomenon.
• The sound of liquid flowing comes from the device:
This sound is normal.
• When the device is turned on, the compressor make loud sounds:
It is normal for the compressor to make a loud noise when starting.
• The device does not work:
- Check whether the device is connected to the power source.
- Check whether the device has been turned on with the On/Off button.
- Check whether the power supply is operational.
- Check whether the fuse has not blown.
• Error codes on the display:
- Error F1 – Supply voltage too low – Check the battery charge level and the correct connection of the device to the power supply in accordance with the device's
technical data. Change the battery protection settings to eadi level.
- Error F2 – Fan overload – Disconnect the device from the power supply and wait at least 30 minutes before restarting it. If the problem persists, contact the
manufacturer's service center.
- Error F3 – Compressor overload – Disconnect the device from the power supply and wait at least 30 minutes before restarting it. If the problem persists, contact
the manufacturer's service center.
- Error F4 – Compressor start error – Disconnect the device from the power supply and wait at least 30 minutes before restarting it. If the problem persists, contact
the manufacturer's service center.
- Error F5 – Compressor overheating – Disconnect the device from the power supply and wait at least 30 minutes before restarting it. Make sure the device is not in
a sunny place and the ambient temperature does not exceed +43°C. If the problem persists, contact the manufacturer's service center.
- Error F6 – Parameter reading error – Disconnect the device from the power supply and wait at least 30 minutes before restarting it. If the problem persists, contact
the manufacturer's service center.
- Error F7 and F8 – Temperature sensor damaged – Report the fault to the manufacturer's service center.
15 A
102mV
4.8 mΩ
340 A²s