Refrigerator
compartments
are too warm
Food is frozen
There is"water flow"
noise from inside the
refrigerator
There are water drops
around the refrigerator
casing or door gap
The compressor is
slightly noisy when
starting
Code F1displayed
Code F2 displayed
Code F3 displayed
start delay of the compressor
·The door is opened frequently.
·A large amount of warm or hot food was stored
recently
·The refrigerator has been disconnected for a
long time
·The temperature was set too low
·It's a normal phenomenon,caused by the flow of
refrigerant.
·It's a normal phenomenon,the moisture will
condense to water when it touches a cold surface
of the refrigerator.
It's a normal phenomenon,the noise will be
reduced after the compressor works stably
·Possible cause:low voltage to fridge.
Adjust the battery protection from High to
Medium or from Medium to Low
·Possible cause:condenser fan is overloaded.
Disconnect power to fridge for 5 minutes
&re-start.
If the code shows again,contact manufacturer for
service
·Possible cause:the compressor starts too
frequently
Disconnect power to fridge for 5 minutes
&re-start
lf the code shows again,contact manufacturer for
service
- 11 -