: Water flow not detected
Comments : The normal operating range for flow rate is between 2 m
If the daily filtration time is divided into several ranges and the range times are shorter than the
processing time then this error may temporarily appear during breaks between ranges until
the processing time is completed on the subsequent range.
Solutions : Check the following:
• The filtration time is sufficiently long to encompass the entire length of the treatment.
• The bypass is providing enough water to the cell and the valves are correctly set.
• The filter is not clogged/obstructed (clean if necessary).
• The flow rate of the rate is sufficient.
• The presence of debris/scale deposits in the cell may obstruct the flow sensor (clean if
necessary following "Cleaning the cell", page 38).
If all of the steps above have been followed and the error persists, contact customer service
for a replacement flow sensor.
E5
: Salt concentration is too low
Comment : The normal operating range for salt concentration 2,700 to 4,500 ppm.
Solutions : Test the salt concentration of the water.
If necessary, add salt until reaching 3 g/l; ensure the chlorinator is switched off until the salt
has fully dissolved (see "Adding salt", page 32).
Once the correct level has been reached, the chlorinator should operate normally again.
E7
: Fatal error in temperature sensor
Solution : Contact customer support for a replacement temperature sensor.
E8
: Transformer output voltage error
Solution : Contact customer support for a replacement transformer.
E9
: Output current error
Solution : Contact customer support for a replacement transformer or cell.
EA
: Cell error
Solutions : Test salt concentration and correct if necessary.
If the error persists, contact customer support for a replacement cell.
EC
: Electronics error
Solutions : Unplug the transformer, wait one minute, then plug back in.
If the error persists, contact customer support for replacement circuit boards.
42
TROUBLESHOOTING
/h and 10 m
/h.
3
3