TECHNICAL INSTRUCTIONS FOR INSTALATION AND REGULATION
Can be used ONLY by specialized technicians. following instructions apply to the technician specialized in
instalation to do all the operations in the most correct way and according to the valid standards.
Important
Any activity connected with regulation etc. must be done only when the device is disconnected from electricity.
If it is necessary to have the device connected to the electricity (during repairs) you must be very careful.
PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the function of the device
(technician must go by valid standard (ČSN....). If the device is situated close to the wall or if it is in contact with
the furniture walls, these walls must resist the temperatures ranging to 60°C. Instalation, setting, putting into
operation must be done by qualifi ed person who is competent for this and according to the valid standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal
surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.The
device can be instalated separately or in a set with devices of our production. Min. distance 10 cm from other
subjects must be kept.It is also necessary to prevent our product from contact with combustible materials. In this
case you must make corresponding changes to secure heat izolation of combustible parts. Safety measures
from the standpoint of the fi re protection according to ČSN 061008čl. 21:
SAFETY MEASURES FROM THE STANDPOINT OF THE FIRE PROTECTION ACCORDING
TO ČSN 061008 ČL. 21
• only adults can operate the device
• device must be safely used in common surroundings according to ČSN 332000-1
• device must be placed so as to stand or hang on the noncombustible surface. No subjects from combustible
materials can be placed directly on the device or in distance which is shorter than safety distance (the shortest
distance is 10 cm).
• safety distances from various materials of different degree of combustion and information about the degree of
comb. of common building materials - see chart:
Chart:
Combustion degree of building materials classifi ed according to the combustion degree of materials and products
(ČSN 730823)
A noncombustible
B uneasily combustible
C1 hardly combustible
C2 middle combustible
C3 easily combustible
Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and
hygienic orders according to:
• ČSN 061008 fi re protection of local devices and sources of heat
• ČSN 332000 surrounding for electric devices
Connecting the oven to the mains
If multiple ovens are connected in a linear fashion they must be grounded among each other at the specifi ed
point, which is located on the rear of the device. This point is identifi ed as the point of equipotential connection
(pic. 2).
granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster
akumine, heraklite, lihnos, itavere
leafy wood, plywood, sirkoklit, rare paper formica
fi breboards, solodure, cork boards, rubber,fl oor-coverings
wood-fi breboards, polystyrene,polyurethane, PVC