Connecting the
NOTE!
sensor
The wirefeeder and/or SplitBox recognises that there is a sensor connected to
the connecting cable. Only use the supplied connecting cable for each sensor.
The connecting cable for the sensor is labelled with the item number and name
of the sensor.
(4)
Adjusting the
OPT/i WF R wire
end ring sensor
(1)
(3)
(2)
(1)
(2)
(3)
NOTE!
The plug (1) of the connecting cable
must only be connected to the sensor
connections (2) that are colour-coded
red (3).
Connector (1) from the connecting
1
cable to the OPT/i Ext connection.
Connect the sensor plug (2) of the
wirefeeder or the SplitBox.
Connect the plug (4) to the sensor.
2
Rotate the wire electrode in the
1
opening (1) of the sensor during
the entire adjustment process
-
LED (3) lights up when the sen-
sor detects the wire electrode
Turn the adjusting screw (2) back
2
until the LED (3) goes out
-
Wire sensor is deactivated
Slowly turn the adjusting screw (2)
3
forwards again until the LED (3)
lights up - stop turning as soon as
the LED lights up
-
The sensor is now set at its lo-
west sensitivity level
-
This prevents the wire sensor
from being triggered accident-
ally
17