Herunterladen Diese Seite drucken

Pipeline box DNA60 Gebrauchsinformation Seite 14

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TC-MODE // NiFe30
A temperature-controlled profile specially designed for nickel-iron wires
(30% nickel content).
TC-MODE // SS316L
A temperature-controlled profile specially designed for stainless steel wires
(V4A / 1.4404 / X2CrNiMo17-12-2 / AISI 316L).
TC-MODE // SS304
A temperature-controlled profile specially designed for stainless steel wires
(V2A / 1.4301 / X5CrNi18-10 / AISI 304).
TC-MODE // Titanium
A temperature-controlled profile specially designed for titanium wires.
TC-MODE // Ni200
A temperature-controlled profile specially designed for nickel wires.
TC-MODE // Zirconium
A temperature-controlled profile specially designed for zirconium wires.
LOCKING THE RESISTANCE
To use the temperature control of your PIPELINE BOX DNA60, you must lock the
resistance [Ω] before using a new atomizer/coil. If a temperature-controlled operating
mode is already active, and the resistance [Ω] of the newly screwed-on atomizer
significantly differs from the previously locked one, a prompt will appear after a brief press
26 English
of the fire button, saying "New Coil? UP YES / DOWN NO." In this situation, you can use
the (+) button to lock the new resistance [Ω] (recommended) or use the (-) button to keep
the previously set one.
The locking of the resistance [Ω] can also be done manually. To do this, first activate the
button lock of the device by pressing the fire button 3 times in rapid succession. Then,
hold down the fire button and the (+) button for 2 seconds. The locking of the resistance
[Ω] will be confirmed by a lock symbol next to the displayed resistance (replacing "Ω").
Repeat the process to release the fixation.
Make sure to lock the resistance only with cold atomizers/coils (room temperature),
otherwise, the displayed temperature [F/C] may significantly differ from the actual
one!
ADJUSTING THE POWER
If the device is in power control mode (watts), use the navigation buttons to increase
(+) or decrease (-) the power [W]. Holding down one of the buttons will increase the
adjustment speed. If the device is in a temperature-controlled operating mode, first
activate the button lock of the device by pressing the fire button 3 times in rapid
succession. Then, hold both navigation buttons simultaneously for 3 seconds to change
the power [W] that the device delivers until the temperature control automatically limits
the power. After making the adjustment, confirm the desired value with the fire button.
ADJUSTING THE TEMPERATURE
To change the set temperature [F/C], the device must be in a temperature-controlled
operating mode. Use the navigation buttons to increase (+) or decrease
(-) the temperature [F/C]. Holding down one of the buttons will increase the adjustment
speed.
English
27

Werbung

loading