Herunterladen Diese Seite drucken

Sharp OT-CD20H Serviceanleitung Seite 12

Werbung

| CT-CD20H
MECHANISM SECTION
- Driving Force check
- Torque Check
Specified
val
Play: TW-2111
30 to 65 g.cm
Fast forwerd: TW-2981
| 65t0 138 90m
Rewind:
TW-2231
* Head Azimuth
MTT-113C
- Tape Speed
Instrument
Connection
Headphones
socket
Adjusting Point | Specified value
Test Tape
MTT-114
in motor
3,000 + 90 Hz
TAPE SECTION
- Bias Oscillation check
Specified value
A: 85 + 4 kHz
B: —5
+ 2 kHzforA
C: -13
£2 kH2forA
Beat cancel
- Erase Current check
- Playback Amplifier Sensitivity check
Test Tape
Specified value
Speaker terminal
MTT-118
1.5V = 3 4B
(Load resistance:
3 ohms)

Werbung

loading

Diese Anleitung auch für:

Ot-cd20hbk