Faults: causes and elimination
Fault
Reason
Machine does not
Interruption of at least 2 lines of the power
supply
start
(makes no noise)
Mains voltage/frequency do not match the
motor data
Connection to the motor terminal board is
not correct
Motor circuit breaker is too small or set too
low
Overload
Machine does not
Interruption of a line of the power supply
start
(makes noise)
Impeller is stuck
Roller bearing defective
Circuit breaker of the
Motor overloaded
motor triggers after
switching on again.
Short circuit in the winding
Impeller is stuck
No or too low pres-
Wrong direction of rotation
sure difference
Machine is leaking
Radial shaft seal ring is defective
Intake filter or air supply is blocked.
Density of the conveyed medium is higher
or lower than permitted.
Impeller dirty
Unusual flow noise
Flow speed too high
Silencer dirty
Vibrations or unusual
Roller bearing defective
running noise
Too high vibration
Spring elements defective
Machine is leaking
Radial shaft seal ring defective
Seal on the silencer is defective or screws
are loose
Machine gets too hot
Insufficient cooling air flow
Insufficient flow rate of conveyed medium
Intake filter or air supply is blocked.
Intake or ambient temperature too high
* These repair works may be carried out by qualified personnel if the repair instructions are available
If you have any other problems, contact AIRTECH Europe.
Countermeasure
Check the functionality of fuses, terminals
or supply lines
Check the motor rating plate data, change
the supply voltage
Check the terminal board wiring
Change the trigger value of the circuit
breaker or replace the circuit breaker.
Reduce throttling
Check the functionality of fuses, terminals
or supply lines
Open and clean compressor lid
Change roller bearing
Reduce throttling. Clean filters, silencers,
air supply lines.
Check winding
Open and clean compressor lid
Check direction of rotation, exchange con-
necting cables if necessary
Seal the system
Change radial shaft seal ring
Clean filters, sieve, silencers, air supply
lines.
Conversion of pressure values, contact
with the manufacturer
Clean impeller, have it replaced when worn
Clean pipes or hoses or enlarge cross sec-
tion.
Clean silencer.
Renew roller bearing
Renew spring elements
Renew radial shaft seal ring
Check seal and replace if necessary or re-
tighten screws.
Clean fan cowl, fan outlet and cooling fins.
Check minimum clearances (see chapter
"Installation")
Provide a suitable vacuum or pressure re-
lief valve.
Clean filters, sieve, silencers, air supply
lines.
Check ambient conditions, compare with
rating plate data
31
Jurisdiction
Electrician
Electrician
Electrician
Electrician
qualified technician*
Electrician
AIRTECH Service
AIRTECH Service
qualified technician*
Electrician
AIRTECH Service
Electrician
qualified technician*
AIRTECH Service
qualified technician*
qualified technician*
AIRTECH Service
qualified technician*
qualified technician*
AIRTECH Service
qualified technician*
AIRTECH Service
qualified technician*
qualified technician*
qualified technician*
qualified technician*
qualified technician*