Spezifikationen
ethernet mac show
ethernet link show
ethernet phyprefer set {10MBIT_HD=0|
10MBIT_FD=1|100MBIT_HD=2|100MBIT_FD=3}
ethernet phyprefer show
extsensor
extsensor all show
extsensor all show
extsensor {port_num} {sen_field} value show
extsensor {port_num} {sen_type} label set "{na-
me}"
extsensor {port_num} {sen_type} label show
extsensor {port_num} type show
extsensor {port_num} {sen_type} {sen_field}
events set {off=0|on=1}
extsensor {port_num} {sen_type} {sen_field}
events show
extsensor {port_num} {sen_type} {sen_field}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5,EVT_DISPLAY=6,EVT_CONSOLE=7}"
extsensor {port_num} {sen_type} {sen_field}
events type show
extsensor {port_num} {sen_type} {sen_field}
events beeper mode set {CONTINOUS=0|
INTERMITTENT=1}
extsensor {port_num} {sen_type} {sen_field}
events beeper mode show
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
extsensor {port_num} {sen_type} {sen_field}
maxval show
extsensor {port_num} {sen_type} {sen_field} min-
val set {num}
extsensor {port_num} {sen_type} {sen_field} min-
val show
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
extsensor {port_num} {sen_type} {sen_field} hyst
show
extsensor {port_num} {sen_type} {sen_field} pu-
blish mode set {NONE=0|INTERVAL=1|
DIFFERENCE=2}
extsensor {port_num} {sen_type} {sen_field} pu-
blish mode show
extsensor {port_num} {sen_type} {sen_field} pu-
blish trigger set {float}
extsensor {port_num} {sen_type} {sen_field} pu-
blish trigger show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
extsensor beeper set {OFF=0|ON=1}
extsensor beeper show
http
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=2}
http server show
http port set {ip_port}
http port show
http portssl set {ip_port}
79
Expert Power Control 8031/8035
shows MAC address
shows ethernet link state
sets preferred speed for PHY Auto Negotiation
shows preferred speed for PHY Auto Negotiation
enters cmd group "extsensor"
shows all values from connected external sensors
shows all plugged sensors and fields
shows sensor value
sets sensor name to label
shows label of sensor
shows type of sensor
enables sensor events on/off
shows if sensor events are enabled
enables different event types
shows what event types are enabled
sets beeper tone
shows beeper tone
sets maximum value for sensor
shows maximum value for sensor
sets minimum value for sensor
shows minimum value for sensor
sets hysterese value for sensor
shows hysterese value for sensor
sets publish mode
shows publish mode
sets trigger value for publish
shows trigger value for publish
sets Port for Power Port Switching actions
shows Port for Power Port Switching actions
sets Port state for Power Port Switching actions
shows Port state for Power Port Switching actions
sets sensor Min/Max measurement period
shows sensor Min/Max measurement period
enables beeper sensor alarms
shows if beeper sensor alarms are enabled
enters cmd group "http"
sets connection types the webserver accepts
shows webserver accepting connection types
sets http port
shows http port
sets https port
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
© 2021 GUDE Systems GmbH