Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanical Data - schmersal AZ 17-02ZRK Bedienung Und Montage

Vorschau ausblenden Andere Handbücher für AZ 17-02ZRK:
Inhaltsverzeichnis

Werbung

Safety classification
Standards
Performance Level, up to
Category
B
Normally-closed contact (NC)
10D
Note
Mission time
Safety classification - Fault exclusion
Please note:
Performance Level, up to
Category
Note
Mission time

Mechanical data

Mechanical life, minimum
Latching force
Positive break travel
Positive break force per NC contact, minimum
Actuating speed, maximum
Mounting
Type of the fixing screws
Tightening torque of the fastening screws for the housing cover,
minimum
Tightening torque of the fastening screws for the housing cover,
maximum
Note
Mechanical data - Connection technique
Cable entry
Termination
Cable section, minimum
Cable section, maximum
Allowed type of cable
EN ISO 13849-1
c
1
2.000.000 Operations
Elektrische Lebensdauer auf Anfrage.
20 Year(s)
Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende
Beschädigung der 1-kanaligen Mechanik zulässig ist und ein
ausreichender Manipulationsschutz gewährleistet ist.
d
3
bei 2-kanaligen Einsatz und mit geeignter Logik-Einheit.
20 Year(s)
1.000.000 Operations
30 N
11 mm
17 N
2 m/s
Schrauben
2x M5
0,7 Nm
1 Nm
Torx T10
M 16 x 1,5
Schneidklemmtechnik
0,75 mm²
1 mm²
Flexibel
5-11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis