Always make sure that the fence has good contact to the notch on the measuring rod.
»
Do not use the device during thunderstorms/lightning strikes.
»
Do not carry out any repairs on the device yourself. Contact the manufacturer
for repairs.
»
Do not make any unauthorised changes or modifications to the device.
WA RNI NG
»
Only use batteries that are suitable for the device (9V block battery).
»
Observe and follow the instructions on the battery.
Intended Use
You can use the VOSS.farming iFence Inspektor to measure the voltage on your electric fence. No other
use is permitted. The device is intended for private use only.
Initial configuration
The tester must be first tuned to the pulse of the energiser (positive
is shown on display).
1. Go to the point where the fence connection cable is connected to the fence.
2. Hold the tester against the conductor and push the button (6).
3. If the arrow (7) points away from the energiser then the tester is correctly set.
If the arrow points toward the energiser then the polarity must be changed, i.e.:
1. Remove the tester from the fence.
2. Push the button (6) for 10 seconds. After 10 seconds the tester beeps. Continue to hold the button
(6). After another 5 seconds the tester beeps again and the polarity changes from
vice versa.
Functionality
Current seeks the path of least resistance. If there is a short circuit (e.g. vegetation) on the fence then
more current will flow in that direction.
With the aid of the tester you are able to ascertain where there is a "leakage" in your fence system. Once
the "leakage" is eliminated the voltage on the fence rises and with it the impulse strength.
The Display
An arrow points in the direction of the leakage (>4 amps). The current value is briefly shown in the top
right corner of the display, before the fence voltage appears.
Tone
When the tone is switched on, the tester beeps with every fence pulse.
Switching the Tone on or off:
1. Remove the tester from the fence until no pulse is shown.
2. Hold the button (6) down for 10 until the beep. Release the button (6).
The tone is now deactivated or activated.
Battery
If the battery symbol flashes then the 9V battery must be replaced.
The battery is replaced by opening the housing.
You need a 9V block battery to operate the TESTER.
Using the Tester on the Fence
1. Start close to where the fence connection cable is connected to the fence.