6.1
ROUTINE MAINTENANCE
The device does not require any routine maintenance.
7
DIAGNOSTICS, PROBLEMS, CAUSES AND REMEDIES
7.1
Disadvantages, causes and remedies table
Disadvantages
The display does not
light up.
Insuffi cient
water
cooling.
Insuffi cient
water
heating.
On the display ap-
pears the message
"P1".
The temperature dis-
played is not the real
one.
WARNING: Before you unplug the machine from the pipes it is necessary to turn off the device
and unplug all electrical plugs from the equipment connected to the aquarium.
Close also the pipes to prevent water leakage.
12
C H I L L E R L I N E
Causes
Lack of electric sup-
ply.
Insuffi cient water fl ow.
Aquarium isolation is
not enough.
Dirty air fi lter.
Ambient temperature
too high.
Outgoing air from the
ventilation grid at room
temperature.
Ventilation
system
clogged.
Broken
ventilation
system.
Insuffi cient water fl ow.
Faulty heater.
Damage of the water's
temperature probe.
The water does not cir-
culate correctly inside
the hydraulic circuit.
Long and not insulated
pipes.
Temperature
sensor
not
calibrated
cor-
rectly.
Check if the plug (Rif. A4 Fig. 4) is correctly inserted into the
device.
Make sure that the plug is fully inserted into the power outlet
(Rif. A5 Fig. 4).
Check if the fuse is not burned. (C1 Fig. 4).
Check the proper operation of the pump (not supplied) (Rif.
A1 Fig. 12-13).
Insulate the walls of the aquarium and the pipes to reduce
heat loss.
Clean the air fi lter following the instruction (Chapter 6 Main-
tenance).
Re-establish the optimal ambient conditions.
The maximum ambient temperature allowed is 38°C (100°F).
Lack of gas in the compressor, contact the TECO S.r.l area
retailer.
Free up or clean the metal grid or place the chiller in an ap-
propriate environment .
Contact the TECO S.r.l area retailer.
Check the correct operation of the pump (not supplied) (Rif.
A1 Fig. 12-13).
Contact the TECO S.r.l area retailer.
Contact the TECO S.r.l area retailer.
Check eventually pipes obstructions.
Check the effi ciency of the aquarium's pump (not supplied).
Reduce as much as possible the pipes and insulate them.
Calibrate the temperature sensor as described in paragraph
5.2.2 Thermostat Settings.
Tab. 7-1