Herunterladen Inhalt Inhalt Diese Seite drucken

TECO Tank TK 150 Handbuch Seite 12

Vorschau ausblenden Andere Handbücher für Tank TK 150:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
TANK
5.2
INSTALLATION AND FUNCTIONING OF THE DEVICE
1) Do not install and do not try to repair the product if it was damaged during transport.
2) Do not connect the power cord to the power supply, unless specifi cally required.
3) In order to ensure the correct working of the device in safe conditions, it is absolutely forbidden to expose
the product to atmospheric agents and to direct heat sources (Fig. 1). The temperature of the installation
environment has to be between 5 °C and 38 °C (41 °F – 100 °F).
4) If the device is installed inside a cabinet, open the selected wall for warm air output, while respecting the
recommended minimum distance (Fig. 6).
Opening position hot air outlet
S
150 mm – 5,91 in
T
150 mm – 5,91 in
U > 75 mm – 2,95 in
V
30 mm – 1,18 in
5) In the lower area of the cabinet provide for an opening of 400 cm
the cabinet (Ref. P1 Fig. 7).
6) Lay the tubes as follows:
7) If necessary, insert cable-tie-wrap (Ref. P3 Fig. 8).
8) Insert the joint ( Ref. P4 Fig. 8) in the tube, and bring cable-tie-wrap on the joint ( Ref P5 Fig. 8).
9) Fasten the joint clockwise (Ref. P7 Fig. 9), direct it as needed and tighten it.
10) When connecting the pipes, make sure that the hose from the pump (not supplied) (Ref. A1 Fig. 10-11 ) and
/ or the fi lter assembly (not supplied with the unit) (Ref.A2 Fig. 10) is connected in the position indicated with
IN (Ref. P8 Fig. 9), the return pipe is connected to the aquarium in the position indicated with OUT (Ref.P9
Fig.9).
11) Install the unit in the chosen place allowing the visibility of the equipment.
12) Start the pump, make sure that the water fl ows regularly in the circuit and that there are no leaks. In the case
of anomalies or leakage in the hydraulic circuit, review the connections.
13)
WARNING: Make sure that the water that reaches the device is fi ltered.
14) Make sure that the power supply requirements match those shown on the technical plate, visible on the back
of the unit (Ref. A3 Fig. 4).
15) When the aquarium pump is functioning, connect the cable power supply fi rst on the device ( Fig. 4 ref A4 )
then to the power socket with the plug (Ref. A5 Fig. 4).
Then the display will show OFF. Pressing the power button (Ref. A7 Fig. 12) for at least 3 seconds, your de-
vice will start working, on the display it is indicated the actual water temperature. To display the temperature
to be reached press the SET button (Ref.A8 Fig. 12) to return to the water temperature press the SET button
(Ref.A8 Fig. 12) or wait for 5 seconds.
16)
WARNING: A 2-minutes delay was added to prevent compressor failure at the fi rst start.
17) To stop the device, press the power button (Ref. A7 Fig. 12) for at least 3 seconds, the display will show
OFF.
10
C H I L L E R L I N E
Minimum distance from walls
Z (air outlet side)
X (side cable exit)
Y (Lateral side)
Tab. 5-1
- 62 in
to allow the entrance of air inside
2
2
EN
0-10 mm – 0 - 0,39 in
60 mm – 2,36 in
50 mm – 1,97 in

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis