Safety advice:
The pump is constructed for indoor aquarium use only. Before working on the
aquarium or pump, the power plug must be disconnected from the mains.
The connection cable and the power plug must not be changed. If the power cable is
damaged, the pump must not be taken into operation.
If the pump is used submerged, the filter (11, 12), hose and/or hose connection (13)
must be used.
6. Maintenance / Cleaning
CAUTION:
Disconnect the power before you start any work on the pump.
The pump is designed to have a low maintenance requirement and, under normal conditions, will
be very reliable. However, the filter housing and all rotating parts must be cleaned regularly (1 to
5).
Remove the pipe connections and undo the bayonet (6) on the pump housing. Now remove the suction
connection (7). Caution: This part is fixed tightly because it has an "O" ring seal and must be removed
carefully so as not to break the ceramic shaft (4).
The complete impeller (4 - 7) can now be taken out, cleaned under running water and be re-
assembled.
7. Failures
If the pump fails to operate check the power connection and fuse. If no fault is found, the pump
may be blocked and must be cleaned – see maintenance / cleaning above.
If the pump is noisy, the pump head (1 to 8) has to be cleaned.
8. Warranty
Should any defect in materials or workmanship be found within twelve months of the date of
purchase AB Aqua Medic GmbH undertakes to repair, or at our option replace, the defective part
free of charge – always provided the product has been installed correctly, is used for the purpose
that was intended by us, is used in accordance with the operating instructions and is returned to us
carriage paid.
Proof of purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase, or a guarantee card if appropriate. This
warranty may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations or
damage is caused by accident, misuse or neglect.
We regret we are unable to accept any liability for any consequential loss.
Please note that the product is not defective under the terms of this warranty where the product,
or any of its component parts, was not originally designed and / or manufactured for the market in
which it is used.
These statements do not affect your statutory rights as a customer.
If your AB Aqua Medic GmbH product does not appear to be working correctly or still appears to be
defective having followed the instructions in 6. & 7. above, please contact your dealer in the first
instance.
Before calling your dealer please ensure you have read and understood the operating instructions.
If you have any questions your dealer cannot answer please contact us
We reserve the right to make technical changes to this product.
AB AQUA MEDIC GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
8
- Technical changes reserved -

Werbung

loading

Diese Anleitung auch für:

Ocean runner ph 2500Ocean runner ph 3000