Programming
1
Mode/Enter Set
Mode/Enter Set
2
3
Mode/Enter Set
Change more parameters:
4
Start again with step 1.
*Decrease the value: Let the display of the parameter value move to the
maximum setting value. Then the cycle starts again at the minimum setting
value.
Select the display unit (Uni) before setting the switch points (SPx, rPx) or the
limits for the analogue output signal (ASP, AEP). This avoids rounding errors
generated internally during the conversion of the units and enables exact set-
ting of the values.
If no button is pressed for 15 s during the setting procedure, the unit returns
to the Run mode with unchanged values.
The unit can be electronically locked to prevent unwanted adjust-
ment of the set parameters: Press both pushbuttons for 10 s (the unit
must be in Run mode). Indication goes out briefly (acknowledgement
of locking / unlocking).
Units are delivered from the factory in the unlocked state.
With the unit in the locked state
to change parameter values.
26
Press the Mode/Enter button
several times until the respective
parameter is displayed.
Press the Set button and keep
it pressed. The current parameter
value flashes for 5 s,
then the value is increased*
(incremental by pressing briefly or
scrolling by holding pressed).
Press the Mode/Enter button
briefly (= acknowledgement).
The parameter is displayed again,
the set parameter value
becomes effective.
Finish programming:
Wait for 15 s or press the
Mode/Enter button until the current
measured value is indicated again.
is indicated briefly when you try