Function and features
• The pressure sensor detects the system pressure,
• shows the current system pressure on its display,
• and generates 2 output signals according to the set output
configuration.
Analogue output
(only output 2)
Switching function
(output 1 and output 2;
function can be selected for
each output separately)
Output polarity (applies to both
switching outputs)
Applications (Type of pressure: relative pressure)
Order no.
PF2053
PF2054
PF2056
PF2057
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
Measuring
range
bar
-1.0 ... 25
PSI
-15 ... 363
MPa
-0.1 ... 2.5
bar
-0.5 ... 10
PSI
-7 ... 145
kPa
-50 ... 1 000
bar
-0.13 ... 2.50
PSI
-1.8 ... 36.3
kPa
-13 ... 250
mbar
-50 ... 1 000
PSI
-0.7 ... 14.5
kPa
-5.0 ... 100
Output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
p-switching (PnP)
n-switching (nPn)
Permissible
overl. pressure
100
1 450
10
50
725
5 000 (5 MPa)
20
290
2 000 (2 MPa)
10 000 (10 bar)
145
1 000 (1 MPa)
Output 2
I: 4 ... 20 mA
U: 0 ... 10 V
Bursting
pressure
350
5 070
35
150
2 175
15 000 (15 MPa)
50
725
5 000 (5 MPa)
30 000 (30 bar)
450
3 000 (3 MPa)
21

Werbung