3. Starting the pump
Giving the different provisions applicable to the safety of electric systems
in different countries, make sure that the pump system, as concerns its
intended use, is in accordance with current legislation.
Before starting the pump make sure that:
• the voltage and frequency specified on the pump's nameplate
coincide with those of the available power supply;
• there are no signs of damage to the pump or its power cord;
• the electric connection is made in a dry place, protected against any
risk of flooding;
Installation
The well dimensions must be such as to prevent an excessive number of
starts per hour.
Improper adjustments may cause malfunctions.
Use short circuit breakers to prevent danger of electrical shock
Operation
• Check water level. The AS submersible pumps can only operate
continuously if it is completely submersed. If the pump is operated
continuously for an extended period of time in a dry condition or at the
lowest water level, the motor protector will be activated. Constant
repetition of this action will shorten pump service life. Do not start the
pump again in such a situation until after the motor has completely cooled.
• Test correct working of the pump
For pump without floatswitch just turn the pump on and off a couple
-
of times to check for normal pump start.
For pump with floatswitch make sure the floatswitch is completely
-
raised and then turn on and off a couple of times to check for normal
pump start.
Turn on the pump and check working of floatswitch by lower and
-
raise the floatswitch some times.