From the program select screen, use the STOP or - key to select Acid Lead (Pb) battery type and
then press the START key.
PROGRAM SELECT
Pb BATT
Pb CHARGE
5.0A 6.0V(3p)
By pressing the + and - keys, you can select the different function modes:
Pb CHARGE
Pb DISCHARGE
 Modifying the settings
If you need to modify the charge or discharge settings, press the START key so that the charge/
discharge current or battery voltage (cell count) setting blinks.
Use the + and - keys to increase or decrease the charge or discharge current or the cell count (2V
to 20V – 1P to 10P).
 Launching the charge or discharge
Once you are ready to start the charge or discharge, press and hold the START key for three seconds.
Number of cells
Charge current
Pb-3 5.0A 6.00V
CHG 000:40 00010
Mode
Charge time
www.nvisionweb.net

Lead batteries

Normal charge
Discharge the battery
Battery voltage
Charged capacity
CHG = normal charge mode
DSC = discharge mode