5HVWRULQJ WKH RULJLQDO FRQ¿JXUDWLRQ
This reset deletes all the RTS control points, all the RTS sensors, all the end limit settings and
resets the motor direction of rotation and favourite position.
Only switch off the power for the motor to be reset.
Put the roller shutter in the middle position (if possible).
1) Disconnect the battery for 2 s.
2) Reconnect the battery for 5 to 15 s.
3) Disconnect the battery for 2 s.
4) Reconnect the battery: the roller shutter moves for several
seconds.
If the roller shutter is at the upper or lower end limit, it will
PRYH EULHÀ\
5) Press and hold the PROG button on a Somfy RTS
ORFDO FRQWURO SRLQW . WKH UROOHU VKXWWHU ZLOO PDNH D ¿UVW
movement followed by a second a few moments later. The
PRWRU LV UHWXUQHG WR LWV RULJLQDO FRQ¿JXUDWLRQ
- Completely recommission the Oximo 40 WireFree™ RTS:
See the Oximo 40 WireFree™ RTS guide.
7.4 Battery recharging
If the Oximo WireFree™ Battery has lost a lot of charge, have
it recharged by a professional, using the Somfy compatible
external battery charger (Oximo WireFree™ Power Supply,
not supplied).
Any use of another battery charger is prohibited.
Do not exceed the maximum charging time of 3.5 hours.
Do not recharge the battery more than 2 times a year.
See Oximo WireFree™ Power Supply guide.
7.5 Battery replacement
See the guide provided by the roller shutter manufacturer
8. Technical data
Type: NiMh with extended voltage range.
Power supply:12 V DC.
Capacity: 2.2 Ah.
Index protection rating: IP X4.
Operating temperature: - 20 to + 70°C.
Max charging time: 3.5 hrs.
Charging frequency: Max 2 per year.
0D[ VWRUDJH WLPH EHIRUH ¿UVW FKDUJH PRQWKV DW & $IWHU VWRUDJH IRU WKLV SHULRG WKHUH LV D ULVN
that the battery may be completely discharged.
Copyright © 2013 Somfy SAS. All rights reserved.
Oximo WirefFree™ Battery câble «Y» OEM
1
OFF
2 sec.
3
OFF
2 sec.
5
K
X2
2
ON
10 sec.
4
ON
M
N
my
19