7.1 Problem with the Oximo WireFree™ Battery?
Problems
The roller shutter is not operational.
7KH UROOHU VKXWWHU VWRSV EULHÀ\ EHIRUH ULVLQJ
when the Up button is pressed.
The roller shutter performs two brief
movements in the same direction, when
the Down button or STOP/my button is
pressed.
The battery is recharged several times in a
year using the external battery charger.

7.2 Replacing a lost or broken RTS control point or RTS sensor

This procedure deletes all of the RTS control points. However, the sensors and the programmed
favourite position and settings made are retained.
Only connect/disconnect the motor to be reset.
Put the roller shutter in the middle position (if possible).
1) Disconnect the battery for 2 s.
2) Reconnect the battery for 5 to 15 s.
3) Disconnect the battery for 2 s.
4) Reconnect the battery: the roller shutter moves for several
seconds.
If the roller shutter is at the upper or lower end limit, it will
PRYH EULHÀ\
5) Press the PROG button on the new RTS control point (L)
until the roller shutter moves up and down: all RTS control
points are cleared and the new RTS control point (L) is
programmed into the motor.
- Repeat the procedures from the "Commissioning" section
- To add RTS control points or RTS sensors:
‡ See the Oximo 40 WireFree™ RTS guide.
18
Possible causes
The wiring is incorrect.
The battery is weak.
One of the components
(motor, solar panel, control
point, etc.) is not working.
The battery is weak.
The battery is low
The solar panel is defective
or damaged.
The battery has reached
the end of its service life.
Copyright © 2013 Somfy SAS. All rights reserved.
Solutions
Check the wiring and modify it if
necessary.
Check that the connection between the
motor and the battery has been carried
out correctly.
Wait while the solar panel recharges the
battery, or have the battery recharged.
See the corresponding guides.
Wait while the solar panel recharges the
battery, or have the battery recharged.
Replace the solar panel(s), see Oximo
WireFree™ Solar Panel guide.
Replace the battery.