CUS400M Instruction Manual
WARNING: No modification of this product is allowed.
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth: 2.5 kVdc.
Primary mains circuits to secondary: 4.25 kVdc
Secondary circuits to earth: 2.5 kVdc.
Safety Approvals:
UL60950-1 and CSA22.2 No.60950-1 - UL Recognised. C-UL for Canada.
UL62368-1 and CSA22.2 No.62368-1 - UL Recognised. C-UL for Canada.
UL/CSA 60601-1/ANSI/AAMI ES 60601-1 - UL + C -UL approval
IEC/EN62368-1 – CE and UKCA mark.
CE marking when applied to any CUS400M product, indicates compliance with the Low Voltage Directive in
that it complies with EN62368-1 and with the RoHS Directive.
UKCA marking when applied to any CUS400M product indicates compliance with the Electrical Equipment
(Safety) Regulations 2016 in that it complies with EN62368-1 and with the Restriction of the Use of Certain
Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
Fusing:
Internal Dual fuses (F1 and F2) in the live and Neutral line, T8AH, 250V. (Standard CUS400M)
Internal Single fuse (F1) in the live line, T8AH, 250V. (Option /E)
Symbols:
N
L
AC
EARTH
Neutral
Live
Caution: See instructions for use
260519-04 Oct 2023