Before using this outdoor fire table, make sure you have read, understand and are following all
information provided in the Important Safety Information section of this manual. Failure to follow
those instructions can cause death, serious injury or property damage.
• Prior to each gas fireplace operation, check the hose and valve for evidence of excessive abrasion or
wear though the visual check hole on the side of the base. Replace visual check cap prior to operating
fireplace.
Burner connections
Make sure the regulator valve and hose connections are securely fastened to the burner and the bottle.
If your unit was assembled for you, visually check the connection between the burner pipe and orifice.
Make sure the burner pipe fits over the orifice.
Checking for Leaks
1. Make a leak check solution by mixing 1-part dish washing soap with 3 parts water in a spray bottle.
2. Make sure control knob is "OFF." Then, turn propane or natural gas on at its source.
3. Spray leak solution on valve connections paying particular attention to the areas indicated by arrows.
4. If any bubbles appear turn propane or natural gas off, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect propane or natural gas source and contact ELEMENTI.
If no bubbles appear after one-minute turn source OFF, wipe away solution and proceed.
Orifice is located
in this connection
Check for leaks at these locations
For Propane/Butane Unit
LEAKAGE TESTING
WARNING
!
Hose Clip Connection
16 / 112
Check for leaks at these locations
For Natural Gas Unit