4. in the configurations menu on the right side, select the
configuration file sent by our offices and select the "apply
configuration" function
4
5. bring the device closer to the IJF from which you want to
apply the configuration (only for NFC connection)
5
6. wait the time necessary to write the configuration in the
instrument and confirm it
D.3 NORMS FOR GOOD MANAGEMENT OF
THE UNIT
The FREEBLOCK units are designed for the conservation of
fresh goods (0 + 8°C) or frozen foods (-18 to -25°C) therefore
it is necessary to keep to the following instructions:
1 – Door opening
Programme the movement of goods so as to reduce the
number of openings of the door and to not concentrate them
over a period of time. Not more than 25 openings in 24 hours.
2 – Daily movement of goods
Do not exceed 30 kgs/
.
3 – Rubber door
On a low-temperature refrigeration cell it is always advisable
to install a rubber door that avoids excessive entries of
external air. It is indispensable in the case of door openings
more than 25 times in 24 hours (see D.4.).
4 - Load limits
The goods stored in the refrigeration cell must not exceed the
minimum limit of the air cooler.
5 – Environmental conditions:
Check that the unit is not exposed to the sun's rays.
Check that the ambient temperature, when near the
condensing unit, be not more than 43°C.
6 – Low-temperature refrigeration cells
ATTENTION: It is indispensable to mount an equalizing valve.
6