0) SAFETY WARNINGS
ATTENTION: DO NOT DAMAGE THE REFRIGERANT
CIRCUIT.
ATTENTION: DO NOT DAMAGE THE INTERNAL OR
EXTERNAL
SIDES
OF
REFRIGERANT CIRCUIT COULD BE DAMAGED. IF SIDES
ARE DAMAGED, DO NOT START UP THE EQUIPMENT
AND CONTACT THE AFTER-SALES SERVICE.
ATTENTION: TO REDUCE THE RISKS CONNECTED WITH
FLAMMABILITY, THIS EQUIPMENT MUST ONLY BE
INSTALLED BY SUITABLY QUALIFIED PERSONNEL
Propane is a natural gas without effects on
the environment, but flammable.
It is therefore essential to ensure that all
the pipes of the refrigerant circuit are not
damaged,
equipment to the power supply.
The installation room must avail of a minimum volume of 1m³
for every 8 grams of refrigerant.
The quantity of refrigerant of the equipment is indicated on the
identification plate. Be careful not to damage the pipes of the
refrigerant circuit during positioning, installation and cleaning.
ATTENTION: AVOID FIRES OR SPARKS INSIDE THE
EQUIPMENT.
In case of damage:
• Keep the equipment away from flames or sources of ignition.
• Ventilate well the environment for a few minutes.
•Turn off the equipment and take out the power plug.
• Inform the after-sales service.
• The more refrigerant the equipment can contain the larger
the environment will have to be in which it is found.
• In environments that are too small, a flammable mix of air
and gas can form.
• THIS MANUAL IS CONTAINED IN THE PACKAGING OF
THE EQUIPMENT. KEEP THE INSTRUCTION BOOKLET
AND, IF THE EQUIPMENT IS SOLD, DELIVER IT TO THE
NEW OWNER.
• THE FREEBLOCK MUST NOT BE EXPOSED OR USED
OUTDOORS. IT MUST BE SHELTERED FROM CLIMATE
CONDITIONS. THE UPPER AND LOWER PART OF THE
EQUIPMENT MUST ALWAYS BE FREE.
• NEVER TOUCH OR MANUVER THE EQUIPMENT IN BARE
FEET OR WITH WET HANDS OR FEET.
• DURING TRANSPORT, ASSEMBLY, TESTING, REPAIR,
USE,
DISASSEMBLY
AND
NECESSARY MEASURES MUST BE TAKEN TO AVOID
RISKS OF TIPPING OVER AND TO GUARANTEE
STABILITY OF THE PRODUCT. INSIDE, THE MANUAL
INDICATES THE MODES OF TRANSPORT, FEATURES
FOR LIFTING THE EQUIPMENT AND FASTENING
INSTRUCTIONS (PARAGRAPH B).
PERSONAL PROTECTION EQUIPMENT IS REQUIRED BY
THE USER.
• AFTER INSTALLING THE EQUPIMENT ENSURE THAT
THE POWER CABLE HAS NOT BEEN CRUSHED OR
DAMAGED.
• TO DETACH THE EQUIPMENT FROM THE POWER
SUPPLY, TAKE OUT THE PLUG. DO NOT PULL THE CABLE
OF THE LATTER.
THE
EQUIPMENT:
THE
before
connecting
the
DISPOSAL
ALL
THE
• DO NOT KEEP EXPLOSIVE SUBSTANCES, SUCH AS
PRESSURISED
CONTAINERS
PROPELLENT IN THIS EQUPIMENT.
• THE EQUIPMENT MUST NOT BE MADE TO WORK WITH
THE FRONT PANEL OPEN DURING TESTING OR REPAIR.
PROLONGED OPERATION IN THIS CONDITION CAUSES
HIGH-PRESSURE BLOCKAGE OF THE SYSTEM. IN THIS
SITUATION RECLOSE THE FRONT PANEL AND WAIT 4
HOURS BEFORE RESTARTING THE SYSTEM.
• THE EQUIPMENT CAN BE USED BY ADULT PERSONNEL
AFTER THEY HAVE RECEIVED INSTRUCTIONS ON THE
SAFE
USE
OF
THE
UNDERSTANDING OF HAZARDS RELATED TO IT.
• DO NOT POWER UP THE EQUIPMENT IF IT IS DAMAGED.
IN CASE OF DOUBT, CONTACT THE RETAILER'S AFTER-
SALES SERVICE.
• IF THE POWER CABLE IS DAMAGED, DO NOT USE THE
EQUIPMENT OR ATTEMPT TO REPAIR IT: IT MUST BE
REPLACED BY THE MANUFACTURER OR BY HIS AFTER-
SALES SERVICE.
• THE REPLACEMENT OF ELECTRIC AND MECHANICAL
COMPONENTS MUST BE DONE EXCLUSIVELY BY
QUALIFIED PERSONNEL. THE USE OF SPARE PARTS
OTHER THAN THOSE INDICATED IN THIS MANUAL MAY
CAUSE RISKS TO THE HEALTH AND SAFETY OF THE
OPERATOR.
• DO NOT USE MECHANICAL DEVICES OR OTHER MEDIA
DIFFERENT FROM THOSE RECOMMENDED BY THE
MANUFACTURER TO ACCELERATE THE DEFROSTING
PROCESS.
• DO NOT USE ELECTRICAL EQUIPMENT INSIDE THE
COLD ROOM IF IT IS NOT OF THE TYPE RECOMMENDED
BY THE MANUFACTURER.
• THE EQUIPMENT HAS A SOUND PRESSURE EMISSION
LEVEL LOWER THAN 70dB(A).
PERSONAL PROTECTION EQUIPMENT IS REQUIRED
DURING
TRANSPORT,
DISASSEMBLY AND REPAIR.
PERSONAL PROTECTIVE EQUIPMENT REQUIRED BY
THE USER
WITH
FLAMMABLE
EQUIPMENT
AND
THE
ASSEMBLY,
TESTING
- 16 -