Herunterladen Diese Seite drucken

STIEBEL ELTRON HSBB 180 Plus Bedienung Und Installation Seite 30

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTALLATIoN
Safety
INSTALLATIoN
8.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
8.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for the unit
are used.
8.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
9.
Appliance description
9.1
Standard delivery
The following are delivered with the appliance:
- Operating and installation instructions for the WPM heat
pump manager
- Outside temperature sensor AF PT
- 3 adjustable feet
- Drain hose
- DHW circulation line and flat gasket union nut
9.2
Accessories
Required accessories
Safety assemblies and pressure reducing valves are available
to suit the prevailing supply pressure. These type-tested safety
assemblies protect the appliance against impermissible excess
pressure.
Required for area cooling:
- Pt1000 temperature sensor
- FET remote control
Additional accessories
- Remote control for heating operation
- High limit safety cut-out STB-FB
- Water softening fitting HZEA
- Segmented anode
- CDT 180 condensate pump and condensate pan (required for
continuous cooling without dew point monitoring)
30
| HSBB 180 Plus|HSBB 180 S Plus
10. Preparation
10.1 Installation site
Material losses
!
Never install the appliance in wet rooms.
Install the appliance near the draw-off point in a dry room free
from the risk of frost. To reduce line losses, keep the distance short
between the appliance and the heat pump.
Ensure the floor has sufficient load bearing capacity and evenness
(for weight, see chapter "Specification / Data table").
The room must not be subject to a risk of explosions arising from
dust, gases or vapours.
If you are installing the appliance in a boiler room together with
other heating equipment, ensure that the operation of the other
heating equipment will not be impaired.
Minimum clearances
≥100
Minimum ceiling clearance: Without DHW circulation 200 mm,
with DHW circulation 400 mm.
f Maintain the minimum clearances to ensure trouble-free op-
eration of the appliance and facilitate maintenance work.
≥100
www.stiebel-eltron.com

Werbung

loading

Diese Anleitung auch für:

Hsbb 180 s plus