Calibration procedure
OUTSPIDER PA
In order to test the detector, it is necessary to close the cover
correctly
First to proceed with calibration, set correctly the sensibility/
range of the microwave
It is possible to activate the calibration mode that defines the best possible
position of the electronic card, depending on the installation height, and obtains
E
the ideal infrared section detection.
N
1. Place DIP1 in SW2 in ON-OFF-ON or OFF-ON-OFF
The led will flash for few seconds to confirm that the procedure has been
G
activated (calibration mode will be active for 1 hour).
2. Perpendicularly cross the detection area atthe maximum
distance you want to detect.
During a crossing, if the card is not positioned correctly,
not only the buzzer will sound intermittently but the green
(á á á á á ) or yellow (â â â â â ) LED blinks.
During a crossing, if the card is positioned correctly not
only the buzzer will sound continuously but the red LED will
activate.
3. If the YELLOW LED blinks and the buzzer sounds
QUICKLY (0.1 sec beep - 0.1 sec pause), SLIDE DOWN
(â â â â â ) the electronic card by small variations.
If the GREEN LED blinks and the buzzer sounds
SLOWLY (0.1 sec beep - 1.5 sec pause), SLIDE UP
(á á á á á ) the electronic card by small variations.
All manuals and user guides at all-guides.com
Calibration procedure
OUTSPIDER PA WS 4
OUTSPIDER DT WS(UB)(U)
In order to test the detector, it is necessary to close the cover
correctly
First to proceed with calibration, set correctly the sensibility/
range of the microwave
It is possible to activate the calibration mode that defines the best possible
position of the electronic card, depending on the installation height, and obtains
the ideal infrared section detection.
1. OUTSPIDER PA WS 4: Move DIP 2 in SW1 in ON
OUSTSPIDER PA WS (UB)(U): Move DIP 6 in SW1 in ON
(Calibration mode will be active for 1 hour)
2. Perpendicularly cross the detection area atthe maximum
distance you want to detect.
During a crossing, if the card is not positioned correctly,
both LED and buzzer will be activated alternatively, more or
less quickly.
During a crossing, if the card is positioned correctly,
there will be 4 beep of the buzzer and the red LED blinks 4
times, as in a regular alarm transmission.
3. The LED blinks and the buzzer sounds QUICKLY (0.1
sec beep - 0.1 sec pause), SLIDE DOWN (â â â â â ) the
electronic card by small variations.
The LED blinks and the buzzer sounds SLOWLY (0.1
sec beep - 1,5 sec pause), SLIDE UP (á á á á á ) the electronic
card by small variations.
4. OUTSPIDER PA WS 4: Move DIP 2 in SW1 in OFF
OUSTSPIDER PA WS (UB)(U): Move DIP 6 in SW1 in OFF