Herunterladen Diese Seite drucken

Polti Vaporella SUPER PRO Serie Bedienungsanleitung Seite 24

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

power cable, wait for two hour for the appliance to cool, and
then unscrew. Check the condition of the safety cap and seal.
If the cap is in good condition, screw it back on completely. If
steam continues to escape from the cap, take the appliance
to the nearest authorised service centre.
• Periodically check the condition of the safety cap and seal.
Impact and being dropped may compromise the safety of the
cap. Replace with an original spare part or replace the seal.
• If the cap spins freely, this indicates that the boiler is still
pressurised and therefore hot. Never force the cap open,
whether the appliance is switched on or the boiler is switched
off and the appliance is disconnected from the mains. Always
wait for the boiler to cool, opening the cap without force.
• Do not use tools to unscrew the cap. If the cap cannot be
removed, even once the appliance has cooled, go to your
nearest authorised service centre.
• WARNING
has been opened when the boiler is still hot, even if the
appliance is unplugged from the mains. On contact with the
hot, empty boiler, cold water will evaporate producing a
spray of steam which can cause burns. Only fill the boiler
when cold and always keep your face away from the boiler
mouth when filling.
• The use of non-original Polti caps and disregard for the
instructions in this manual constitutes improper use. Polti
S.p.A. declines all liability for any accident deriving from any
improper use of this appliance.
Never fill the boiler as soon as the safety cap
| 23 |

Werbung

loading

Diese Anleitung auch für:

Vaporella super pro 1750