Herunterladen Diese Seite drucken

SuperFish TopClear Filter 5000 Gebrauchsanweisung Seite 7

Vorschau ausblenden Andere Handbücher für TopClear Filter 5000:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Never block the outlet (OUT) or reduce the outlet diameter, otherwise the pressure in the filter may become too high, causing the
filter to leak or break.
• Install and operate the pump and check the system for leakage, make sure all connections are 100% waterproof. Leakage may
lead to an empty pond and cause harm to your fish and plants.
• Check the operation of the UV lamp via the light indicator on the cover (D-b).
Maintenance of the filter
• Always disconnect from the mains supply before carrying out any maintenance!
• Weekly check the Flow Indicator (D-c) if the water flow is sufficient, if the flow decreases you need to clean the filter. Clean the
filter by using the Auto Clean Wash (backwash). After fist installation or if your pond is heavily polluted, it may be neccesary to
flush through the filter daily by using the Auto Clean Wash.
• Remove the end cap of the CLEAN exit. Install the suplied hose connection on to the CLEAN exit and attach a pond hose (E-d). Turn
the Auto Clean Wash knob a quater counter clockwise (E-e). The pond pump will flush the water in the opposite direction,
cleaning the filter sponge. You can use this water to irrigate your garden. After cleaning, ALWAYS reinstall the end cap at the
CLEAN exit.
• A optional BackWash Valve is available at your SuperFish dealer, this replaces the end cap on the CLEAN exit and makes the
flushing of the water more easily (BackWash Valve TopClear 5000 art. 06020717, BackWash Valve TopClear 10/15/18000 art.
06020719).
• Yearly the filter needs general maintenance, unplug the Pond pump and TopClear filter from the mains. Remove the pond hoses
from the filter and open the clamps. After the first clamp, open the opposite clamp, etc. (F-f). Then take the lid of the filter.
• Take out the filter sponge and rinse with clean tap water. Replace the filter sponge yearly or more often if needed (F-g).
• Take out the clapboard (not applicable with the TopClear 5000) and rinse with tap water.
• Clean the Bio-Balls in a bucket filled with pond water to maintain bacteria life. Do not use tap water!
• Remove the rubber sealant from the filter housing, check the seal for damage. Replace, after cleaning or replacement, the sealant
back in the upper part of the housing.
• After cleaning, replace the lid in the same position as before and close the clamps properly.
Maintenance of the UVC-unit
• Check monthly if UV lamp is lit through the control window on the cover (D-b).
• Always disconnect from the mains supply before carrying out any maintenance!
• The UVC device and quartz glass should be cleaned yearly or more often if algae growth increases!
• The lamp is hot, wait 10 minutes after switch off before opening the unit.
• Remove the protective cover of the UVC (G-h) by pulling it of the filter cover.
• Slide the red switch lock (G-j) to unlock the unit head and housing.
• Turn the unit head (G-k) counter clockwise against the stop, then carefully pull it out of the housing.
• Loosen the screw (H-l), remove the locknut (H-m). Remove the quartz glass including the gasket by a slight rotary movement (H-n).
• Clean the quartz glass outer face with SuperFish UVC Pump & Clean carefully and check for damage.
• Remove the UV-lamp together with UV-tube clip (J-o) and tube protection ring (J-p) and remove the O-ring (J-q) from the unit
head. Clean the unit head and make sure that it's dry, place a new O-ring if necessary.
• Replace the UV-lamp if necessary (recycling). Insert the (replacement) UV-lamp with a UV-tube clip and tube protection ring in
the fitting of the unit head (J).
• Insert the quartz glass with the gasket in the unit head (K), slide the locknut over the quartz glass and tighten it onto the unit
head. Place the screw back and tighten the locknut (L).
• Place the unit head with the fitted UV-lamp and quartz glass back into the housing. Turn it clockwise up to the stop and slide the
red switch lock to the housing (M).
• To avoid UVC overheating, unplug the filter from mains when no water is flowing through the filter.
• In the winter season, when the system is not used, the TopClear filter should be removed to avoid the risk of freezing.
• The UV-lamp should be replaced yearly.
7

Werbung

loading

Diese Anleitung auch für:

Topclear filter 10000Topclear filter 15000Topclear filter 18000Topclear 5000Topclear 10000Topclear 15000 ... Alle anzeigen