Herunterladen Diese Seite drucken

ASO Safety Solutions ELMON rail 32-242 Betriebsanleitung Seite 17

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ELMON rail 32-242
Safety Relais
If there is no fault alarm, the operating state is shown via the LED Power (on). When signalling a fault alarm
the number of pulses emitted indicates the nature of the fault:
Pulse
Fault alarm
1
Supply voltage outside the available range
3
Output control Stop Channel 1 faulty
4
Output control Stop Channel 2 faulty
5
Data transfer between microcontrollers faulty
6
Error in testing signal input (Channel 1 / Channel 2)
6.2 Connection terminals
Pin 1 2
(Not allocated)
Pin 3 11 Signal input Channel 1
Pin 3 10 Signal input Channel 2
Pin 4 5
Relay output to Channel 1 control
Pin 7 8
Relay output to Channel 2 control
Pin 8 9
Supply voltage 24 V AC/DC
7. Mechanical mounting
The switching unit must be mounted correctly:
• In a dust-protected and moisture protected switch cabinet or casing.
• For use in an environment with contamination level 2.
• With a protection type of at least IP54.
• On a 35 mm DIN support rail according to EN 50 022 .
The switching unit must not be installed in the immediate vicinity of an intense heat source.
The switching unit can be installed in any position.
The unit must not be operated in areas with major temperature changes.
6
5
7
8
4
9
3
10
2
11
1
17

Werbung

loading