Herunterladen Diese Seite drucken

Techly ICA-PLB 162M Bedienungsanleitung Seite 6

Werbung

3
q
Q
1
1
2
2
1
EN
Mounting the Wall Plate to the Wall
Brick, Solid Concrete and Concrete Block mounting: Use
the wall plate as a template to mark 4 hole locations on the
wall. Two in the top row of slots and two more in the bottom
row. Make sure these holes are leveled and there is at least
6" (150mm) distance between any two holes. Pre-drill these
holes with a 3/8" (10mm) masonry bit to at least 2.4" (60mm)
in depth. Insert a concrete anchor (q) into each of these holes.
Make sure. the anchor is seated completely flush with the con-
crete surface even if there is a layer of drywall or other material
in front. Attach the wall plate to the wall using 4pcs lag bolts(o)
c
b ,
and 4pcs lag bolt washers(p), shown in diagram.
Montaggio della placca a muro sul muro
IT
Installazione su mattone, cemento armato o blocchi di
calcestruzzo. Utiliizare la placca a muro come sagoma per
segnare la posizione dei 4 fori da effettuare sul muro. Due
fori sono situati nella parte superiore e altri due nella parte
a
inferiore della staffa. Assicuratevi che i fori siano a livello e che
ci siano almeno 150mm (6") di distanza tra due fori. Praticare
i fori con una punta da trapano da 3/8" (10mm) in modo tale
che abbiano almeno 2.4" di profondità (60mm). Inserire un
l
a l
w
tassello (q) in ciascuno di questi fori. Assicurarsi che ciascun
tassello sia inserito completamente e sia a filo con la superficie
in calcestruzzo, anche se, frontalmente, vi è uno strato in
cartongesso o di altro materiale. Fissare la placca a muro
al muro utilizzando le 4 viti per i tasselli (o), le 4 rondelle dei
tasselli (p) come mostrato nello schema.
6
MULTIPLE DESKTOP MONITOR ARM WITH CLAMP
A
3
m
a
g r
a
D i
1
1
2
2
p
P
60 mm
2
ø 10 mm
A
4
m
a
g r
a
D i
www.techly.com
SLIM LCD LED TV FIXED WALL MOUNT
p
P
o
o
O
O
1
1
1
EN
Wood stud mounting:
The wall plate must be mounted to two wood studs at least
16"(406mm) apart. Use a stud finder to locate two adjacent
studs. It is a good idea to verify where the studs are located
with an awl or thin nail shown in the diagram. Pre-drill a 2.4"
(60mm) deep hole at the desired height in each stud using a
5/32" (4mm) drill bit. Make sure these holes are in the center
area of the studs and level with each other. Use the wall plate
as a template to mark the location of the second hole in each
stud. Drill 2.4" (60mm) deep holes using the 5/32" (4mm) drill
bit in the marked locations.Attach the wall plate to the wall us-
ing the 4pcs lag bolts (o) and 4pcs lag bolt washers (p).
Installazione su pareti con intelaiatura in legno
IT
La placca a muro deve essere montata su assi di legno ad
almeno 406mm di distanza. Utilizzate l'apposito strumento
per individuare due assi vicine. Potrebbe essere una buona
idea per verificare dove le assi sono posizionate utilizzare un
punteruolo o un chiodo sottile come mostrato nello schema.
Praticate un foro 2.4" di profondità (circa 60mm) all'altezza
desiderata in ciascuna asse utilizzando una punta da 5/32"
(4mm). Assicuratevi che i fori siano posizionati nella parte
centrale delle assi e che siano allo stesso livello. Utilizzate
la placca a muro come sagoma per segnare la posizione
del secondo foro su ciascuna asse. Praticate gli altri fori con
profondità 60mm (2.4") con una punta da 5/32" (4mm) nelle
posizioni segnate. Fissate la placca a muro. usando le 4 viti
per i tasselli (o) e le 4 rondelle per i tasseli (p).
D ia g r a m 3 A
2
2
2
3
60 mm
D ia g r a m 4 A
b, c
a
wa ll
ø 4 mm