G
B
SYSTEM LAY-OUT
1 - FLUID operator
2 - Tuned aerial
3 - Flashing lamp
4 - Key selector
5 - Photoelectric cells (external)
6 - Photoelectric cells (internal)
Parts to install according to EN 12453 standard
COMMAND TYPE
(out of public area*)
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
PRE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the
movement and must move without frictions.
Before the installation of FLUID, verify all dimensions etc.
There's n o need for any modification, if the gate is like that shown in Pic. 1.
ATTENTION: It is compulsory to conform the gate characteristics to the current regulations
and laws.
TECHNICAL
DATA
Max. leaf length
Max. leaf weight
Average opening time 90°
Average opening range
Max torque
EEC Power supply
Motor capacity
Power absorbed
Capacitor
Guaranteed consecutive cycles
Lubrification
Weight of electroreducer
Noise
Volume
Operating Temperature
Protection
* In the case of leaf longer than 1,8 metres, an electric lock must be fitted to ensure efficient
closing.
1
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E
12
FLUID R - FLUID 2B
m
4*
kg
800
s
13
80°÷100°
Nm
250
230V~ 50/60HzHz
W
230
A
1,1
µF
12
n°
500/13s
OX Super
kg
27
db
<70
0,0275
m
3
°C
-20 ÷ +55
IP
677