3. Safety Guidelines

3.1 Instructions

1. The product must be installed by a licensed electrician.
2. The Home Panel defaults to Grid Mode. For safety, do not access or
disconnect any load circuits when there is an internal fault. Power down
those loads and contact a licensed electrician or Zendure technical support.
3. Do NOT unplug fuses while Home Panel is energized to avoid causing
damage to the Home Panel.
4. All upstream breakers feeding into Home Panel should be non-AFCI or non-
GFCI. AFCI or GFCI protection should be downstream of the Home Panel using
AFCI/GFCI breakers or outlets.
5. Do not use around strong static electricity or magnetic fields.
6. Do not install or operate the product outdoors or expose to moisture or
submerge it in liquid. Only clean the ports with a dry cloth.
7. Do not block or obstruct the cooling fan during use or place the product in an
unventilated or dusty area.
8. Do not install or operate the product in extreme temperatures. Do not
dispose of the product in heat or fire.
9. Do not use the product if it is damaged or appears to be damaged. Do not
disassemble the product. Consult official Zendure channels when service or
repair is required. Incorrect disassembly or reassembly may result in a risk of
fire or injury to persons.
10. Do not connect the relay lines to circuit breakers higher than their current
rating. Doing so can result in damage to the relay modules.
11. Adhere to all local and national safety regulations for installation and use.
12. This product is designed for residential use only. Keep out of reach of
children and pets.
13. The maximum total current for all input circuits under Grid Mode is 60Ax3.

3.2 Warnings

1. To completely de-energize the product, the user MUST open the upstream
breakers as well as physically unplug all SuperBase V's. Failure to do so may
cause a shock hazard.
2. The Home Panel Itself does not provide an AFCI (Arc Fault Circuit Interrupter)
or GFCI (Ground Fault Circuit Interrupter) function. Consult a licensed
electrician for AFCI or GFCI solutions.
3. The Home Panel MUST be completely de-energized before being serviced.
Electrical equipment should be serviced by authorized personnel only.

4. Important Tips

Complete the following steps to de-energize the Home Panel
1. Open all connected upstream circuit breakers and make sure the Grid
Indicator is off.
2. Turn off SuperBase V's, unplug them off the Home Panel and ensure the
ZenX Port Indicators are off.
3. The alarm will sound if the Home Panel is energized while the Front Panel is
open. Please ensure that the unit is de-energized and the alarm has stopped.
2