Herunterladen Diese Seite drucken

Jimi TORE Low Level Montageanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Low Level
Low Level
• Remove the panel sections from top to
EN
bottom. Achieve this by removing the
roller holders and centre hinges.
• Remove the horizontal trackset
• Remove the vertical trackset
16. Maintenance / Warnings
In accordance with EU standards, Industrial door
systems should be maintained and checked regularly,
from the first time of use, based on the indicated
service by the installer. Maintenance needs to be
recorded written.
Maintenance should be only
carried out by an qualified industrial door company
/ installer.
Brackets and other components which are attached to
Torsion Springs and Cables are under extreme tension.
Tensioned springs carry a high tension; always be very
careful, and make sure the tensioning bar (# 12025)
are well maintained and use the right side of the bar
(depends on used spring plug). When checking the
industrial door system, always disconned the electrial
main power supply and make sure that it is blocked
against re-engaging without you knowing it.
Directly after installation (By Installer):
Lubricate the running part of the
tracks (advice: PTFE)
Lubricate bearings and the shaft
of the rollers (advice: PTFE)
Lubricate pins of the hinges from intermediate-
and side-hinges (advice: PTFE)
Lubricate the bearing of the shaft (advice: PTFE)
Lubricate sealing rubbers (advice:
special rubber grease or vasaline)
After 3 months (By Installer):
• Check balancing system / Re-tensioning
springs (relaxation springs)
• Complete visual inspection
Every 6 months (By User):
Check side seals, Top seal and Bottom Seal
on damage or wear and tearLubricate the
running part of the tracks (advice: PTFE)
Lubricate bearings and the shaft
of the rollers (advice: PTFE)
Lubricate pins of the hinges from intermediate-
and side-hinges (advice: PTFE spray)
Lubricate sealing rubbers (advice:
special rubber grease or vasaline)
Clean the panels (advice: shampoo for car cleaning
with water), do not use aggressive detergents
Wax the panels (advice: car wax)
Remove dirt from the door and surroundings
Every 12 months or every 7500 door cycles (By
Installer):
Check the cables and the end connections
from the cable on damages or wear and tear
6
Check the cable connection points on bottom
bracket or cable break device and Cable drum
Check the spring break devices in
accordance with separate manual
heck the position of the ratched wheel
Check the function of the catcher
Check the bolt and screws connection of the SBD
Check the Cable Brack Device in
accordance with the seperate manual
Check the function of the Cable Break Device
Check position of the knife of
the Cable Break Device
Check the position of the hinge pin
Check the balance of the door and adjust
if needed / check the manual operation
Check the hinges on breaking and wear and tear
Check the Pulley system (if present)
for damages or wear and tear
Check or test the fixations of the
springs to the spring plugs
Check the rollers or damages or wear
and tear and free moving space
Check the closing forces of the main
closing edge (Only if Electrical Operation
an Not Deadman function)
Check the suspension from the
horizontal track to the ceiling
Check the suspension profiles
on breaking or damages
Check the bolt and nut connection
Check side seals, Top seal and Bottom
Seal on damage or wear and tear
Check the panels on damage, wear and tear
Lubricate torsion springs, bearings of rollers,
running parts of the track and bearing on the shaft
Every 24 months or every 15000 door cycles (By
Installer):
Check the cables and the end connections
from the cable on damages or wear and tear
Check the cable connection points on bottom
bracket or cable break device and Cable drum
Check the spring break devices in
accordance with separate manual
Check the position of the ratched wheel
Check the function of the catcher
Check the bolt and screws connection of the SBD
Check the Cable Brack Device in
accordance with the seperate manual
Check the function of the Cable Break Device
Check position of the knife of
the Cable Break Device
Check the position of the hinge pin
Check the balance of the door and adjust
if needed / check the manual operation
Check the hinges on breaking and wear and tear
Check the Pulley system (if present)
for damages or wear and tear
Check or test the fixations of the
springs to the spring plugs
Check the rollers or damages or wear
and tear and free moving space
Check the closing forces of the main
closing edge (Only if Electrical Operation
an Not Deadman function)
Check the suspension from the
horizontal track to the ceiling
Check the suspension profiles
on breaking or damages
Check the bolt and nut connection
Check the shaft on damages and wear and tear
Check the connection of the trackset
Check and re-fix the bolt of the coupler
Check side seals, Top seal and Bottom
Seal on damage or wear and tear
Check the panels on damage, wear and tear
Lubricate torsion springs, bearings of rollers,
running parts of the track and bearing on the shaft
17. Replacements of Parts
Only use Original DOCO spare parts!
Maintenance should be only carried out by a
qualified industrial door company / installer.
After Spring Break:
See instructions separate manual (or download the
manual: www.doco-international.com)
Replace the springs and the Spring Break Device
Check the shaft on damages
and replace if necessary
After Cable Break:
See instructions separate manual (or download the
manual: www.doco-international.com)
Replace cable with connection
Replace the complete Cable Break Device
Check tracks and service or replace the tracks
6
6
06-2019 | Low Level
06-2019 | Low Level
EN
7
7
7

Werbung

loading

Diese Anleitung auch für:

Tore vertical lift