Replacing the batteries
1. Connect the gas bottle to a recovery system (fig. 6, page 5).
2. Connect the device to the AC mains using the AC cable
(fig. 1 1, page 3).
3. Connect the "Output" connection to the air conditioning service station
(fig. 2 2, page 3).
4. Connect the gas bottle from which refrigerant is to be recovered to the
"Input" connection (fig. 2 1, page 3).
5. Switch on the device using the on/off switch (fig. 2 3, page 3).
6. Place the filled gas bottle to be emptied on the scale.
7. Wait until the scale has determined the current weight and displayed this.
8. Press the "Recover" button (fig. 3 8, page 4).
9. Enter the weight to be removed (min. 50 g) using the numerical keys.
10.Press the "Enter" button (fig. 3 6, page 4).
✔ The solenoid valve is opened and the refrigerant extracted.
The solenoid value closes when the selected quantity of refrigerant has
been charged.
The device displays the remaining quantity of refrigerant in the filled
refrigerant bottle.
I
NOTE
 Press the "Enter" button fig. 3 6, page 4) to stop a process at
any time. After this press the "Recover" button
(fig. 3 8, page 4) to return to the previous screen.
 If you want to end the charging process before the selected
quantity of refrigerant has been reached, press the "0" button.
Press the "Enter" button (fig. 3 6, page 4) to exit the mode.
6.5
Repeating the process
➤ After charging or recovering, press the "Repeat" button (fig. 3 5,
page 4) in order to charge the previously selected weight again.
7
Replacing the batteries
1. Open the cover on the back of the hand display.
2. Replace the batteries (9 V).
3. Close the cover.