WARNING
!
To avoid unpredictable system behavior that
can cause personal injury and property damage:
• Disconnect electrical supply (when necessary)
before installation, servicing, or conversion.
• Disconnect air supply and depressurize all
air lines connected to this product before
installation, servicing, or conversion.
• operate within the manufacturer's specified
pressure, temperature, and other conditions
listed in these instructions.
• Medium must be moisture-free if ambient
temperature is below freezing.
• Service according to procedures listed in these
instructions.
• Installation, service, and conversion of these
products must be performed by knowledgeable
personnel who understand how pneumatic
products are to be applied.
• After installation, servicing, or conversion,
air and electrical supplies (when necessary)
should be connected and the product tested
for proper function and leakage. If audible
leakage is present, or the product does not
operate properly, do not put into use.
• Warnings and specifications on the product
should not be covered by paint, etc. If
masking is not possible, contact your local
representative for replacement labels.
WARNING
!
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
!
WARNING
FAILuRE oR IMPRoPER SELECTIoN oR
IMPRoPER uSE oF THE PRoDuCTS AND/oR
SYSTEMS DESCRIBED HEREIN oR RELATED
ITEMS CAN CAuSE DEATH, PERSoNAL INJuRY
AND PRoPERTY DAMAGE.
This document and other information from The
Company, its subsidiaries and authorized distributors
provide product and/or system options for further
investigation by users having technical expertise.
It is important that you analyze all aspects of your
application, including consequences of any failure
and review the information concerning the product
or systems in the current product catalog. Due to the
variety of operating conditions and applications for
these products or systems, the user, through its own
analysis and testing, is solely responsible for making
the final selection of the products and systems and
assuring that all performance, safety and warning
requirements of the application are met.
The products described herein, including without
limitation, product features, specifications, designs,
availability and pricing, are subject to change by
The Company and its subsidiaries at any time
without notice.
EXTRA CoPIES oF THESE INSTRuCTIoNS ARE
AVAILABLE FoR INCLuSIoN IN EQuIPMENT
/ MAINTENANCE MANuALS THAT uTILIZE
THESE PRoDuCTS. CoNTACT YouR LoCAL
REPRESENTATIVE.
Safety Guide
For more complete information on recommended
application guidelines, see the Safety Guide
section of Pneumatic Division catalogs or you can
download the Pneumatic Division Safety Guide
at: www.wilkersoncorp.com
Tel: (269) 629-5000
!
You
have selected a quality product, and
we appreciate it... To be assured of maximum
performance and satisfaction please read these
instructions before installing this product.
IMPoRTANT INSTALLATIoN INSTRuCTIoNS
FoR DIAL-AIR™ REGuLAToRS
1. Do NoT install the unit until you have read
this entire product information sheet.
2. EXCEPT
as
otherwise
manufacturer, this product is specifically
designed for compressed air service, and
use with any other fluid (liquid or gas) is a
misapplication. For example, use with or
injection of certain hazardous liquids or gases
in the system (such as alcohol or liquid
petroleum gas) could be harmful to unit or
result in a combustible condition or hazardous
external leakage. Manufacturer's warranties
are void in the event of misapplication and
manufacturer assumes no responsibility for
any resulting loss. Maximum pressure rating
is 300 psig (21 bar). Temperature range is
32°F to 150°F (0°C to 65.5°C).
3. INSTALL upstream of and as close as
possible to where regulated air is needed.
4. INSTALL with air flow in direction of arrow on
casting.
!
5. Do NoT restrict the air flow with undersize
piping or fittings, unless maximum air flow is
not needed.
6. INSTALL regulator in any rotational position.
7. GAuGE PoRTS may be used for installing
!
gauge or they may be used as additional
regulated air outlet ports. Plug all unused ports.
8. PANEL MouNTING requires a 2 11/16" (69
mm) diameter hole, and 4 7/32" (5.5 mm)
screw holes. Unit can be mounted on material
up to 1 1/4" (32 mm) thick.
9. INSTALLATIoN of a 5-micron rated filter
upstream of regulator is recommended.
10. To REGuLATE AIR turn adjustment knob
clockwise to raise the regulated air pressure
and counterclockwise to lower the regulated
air pressure.
IMPoRTANT MAINTENANCE INSTRuCTIoNS
FoR DIAL-AIR™ REGuLAToRS
1. BEFoRE SERVICING THIS uNIT, READ
THIS ENTIRE PRoDuCT INFoRMATIoN
SHEET AND TuRN oFF AIR SuPPLY AND
VENT BoTH SIDES oF REGuLAToR.
LuBRICATIoN oF DIAL-AIR™ REGuLAToRS
1. FoR TRouBLE-FREE oPERATIoN, proper
lubrication of the Dial-Air™ regulator is
essential.
2. WHEN ANY of the following symptoms occur,
lubricate regulator with Magnalube-G
note) If Magnalube-G
Lubriplate, or Molykote. NoTE: Never use oil
as a lubricant.
A. Excessive relief venting.
B. Inability to attain high secondary pressure.
C. Erratic secondary pressures.
D. Excessive hysteresis (a retardation of
desired effect: in this case because of the
lack of lubrication).
Installation & Service Instructions
83-528-000
Dial-Air™ Regulators
ISSuED: March, 2011
Supersedes: September, 2006
Doc. #83528000, EN# 11224, Rev. 5
3. Refer to "Figure A" for steps 1 thru 10.
1. Remove bottom plug (1), main valve
2. Clean main valve molded rubber seat (Do
3. Clean and lubricate bottom plug seal,
4. Reassemble unit.
specified
by
5. If problem is not remedied, lubricate
6. Remove retaining ring (6) and pull bonnet
7. Remove upper piston (8), upper piston
8. Clean and lightly lubricate inside of body.
9. Clean and lubricate upper piston seal,
10. Reassemble unit. If symptoms still exist,
RECALIBRATIoN oF DIAL-AIR™
REGuLAToRS
1. Do NoT ATTEMPT To CALIBRATE uNIT
uNTIL ALL EIGHT SEALS HAVE BEEN
PRoPERLY LuBRICATED.
2. To RECALIBRATE Dial-Air™ REGuLAToR:
A. INSTALL regulator on air line with at least
B. INSTALL an air pressure gauge to one
C. REMoVE lock button (Figure A, Item 14)
D. TuRN adjusting knob to 100 psi (7 bar)
E. CHECK the gauge for 100 psig (7 bar)
F.
G. Do NoT adjust screw "A" more than one-
®
. (See
®
is not available, use
spring (2), main valve (3), pilot valve
spring (4), and pilot valve (5).
not lubricate).
main valve seal and pilot valve seal.
remaining seals. (See steps 6 thru 10)
assembly (7) from unit.
cup (9), lower piston (10), needle valve
(11), and needle valve spring (12).
upper piston cup seal, lower piston seal,
needle valve seal and main valve slide
seal (13).
contact manufacturer.
110 psig (7,5 bar) air pressure at the inlet
port.
of the gauge ports. Plug remaining gauge
port with plug (supplied).
from unit.
setting.
reading. If gauge reads other than 100
psig (7 bar) adjust screw "A" (Fig. B) with
a screwdriver while holding adjusting knob
on 100 psi (7 bar) setting. If more than
one-half turn of screw "A" is required to
achieve 100 psig (7 bar), see "G" below.
To CHECK CALIBRATIoN ADJuSTMENT:
when dial and gauge are reading the
same (100 psig ± 2 psig; 7 bar ± 0,14
bar), turn adjusting knob to 20 psi (1,4
bar). Unit is calibrated when gauge reads
20 psig ± 5 psig (1,4 bar ± 0,34). (The ± 2
psig and ± 5 psig are accepted tolerances
of the most commonly used gauges.)
half turn when calibrating unit. If unit has
been properly lubricated and more than
one-half turn is required to calibrate it,
additional problems with unit are involved
and unit should be returned to the vendor.

Werbung

loading

Inhaltszusammenfassung für Wilkerson Dial-Air R31

  • Seite 1 Installation & Service Instructions 83-528-000 Dial-Air™ Regulators Richland, MI 49083 Tel: (269) 629-5000 ISSuED: March, 2011 Supersedes: September, 2006 ENGLISH Doc. #83528000, EN# 11224, Rev. 5 WARNING 3. Refer to “Figure A” for steps 1 thru 10. have selected a quality product, and To avoid unpredictable system behavior that 1.
  • Seite 2 REMARQuE : L’huile ne doit jamais servir de Guide de sécurité FRENCH lubrifiant. A. Décharge à l’atmosphére excessive. Pour obtenir de plus amples informations sur les directives à appliquer recommandées, prière de B. Incapacité d’atteindre pression AVERTISSEMENT vous reporter à la section Guide de sécurité secondaire élevée.
  • Seite 3 HINWEIS: Niemals Öl als Schmiermittel Sicherheitshinweise GERMAN verwenden. A. Übermäßige Entlastungsentlüftung. Umfassendere Informationen zu den empfohlenen B. Kein hoher Sekundärdruck erzielbar. Anwendungsrichtlinien finden Sie im Abschnitt VoRSICHT Sicherheitshinweise (Safety Guide) in den C. Unregelmäßige Sekundärdrücke. Katalogen der Pneumatic Division, oder Sie D.
  • Seite 4 C. Pressioni secondarie irregolari. Guida della sicurezza ITALIAN D. Isteresi eccessiva (un ritardo dell’effetto desiderato. Il ritardo, in questo caso, è Per maggiori, complete informazioni sulle dovuto alla mancanza di lubrificazione). linee guida di sicurezza raccomandate per AVVERTENZA l’applicazione, vedere la sezione Guida della 3.
  • Seite 5 A. Excesiva pérdida a través de la válvula de Guía sobre la seguridad SPANISH descarga. B. Incapacidad de obtener una presión se- Para obtener información más completa acerca cundaria alta. de los lineamientos recomendados acerca del ADVERTENCIA C. Presiones secundarias erráticas. uso, vea la sección Guía sobre la seguridad en D.
  • Seite 6 FIGURE “A” FIGURE “B” (14) (11) (12) ® Magnalube-G Lubrication (10) Points (13) IMPoRTANT NoTE: As with any new product, everyone seems to have CALIBRATION ADJUSTMENT SCREW an urge to see how it works. All Dial-Air™ regulators have been factory- VIS DE RÉGLAGE DE LA CALIBRATION calibrated.
  • Seite 7 Taille nominale Kit N° de pièce Taille nominale Kit N° de pièce Bouton de réglage RRP-16-024-80 Bouton de réglage RRP-16-024-80 Kit de joints toriques de réparation GRP-95-260-80 Kit de joints toriques de réparation GRP-95-261-80 Kit de réparation de piston et de capuchon RRP-95-765-80 Bas de piston et joint torique RRP-95-192-80 Ressort de détendeur, rondelle belleville, Kit de réparation de piston et de capuchon...
  • Seite 8 D imensioni nominali del corpo Kits Numero di D imensioni nominali del corpo Kits Numero di catalogo catalogo Manopola a quadrante di regolazione RRP-16-024-80 Manopola a quadrante di regolazione RRP-16-024-80 O-ring di ricambio GRP-95-260-80 O-ring di ricambio GRP-95-261-80 Pistone e coperchio di ricambio RRP-95-765-80 Fondo del pistone e tenuta O-ring RRP-95-192-80 Molla, regolazione, molla a tazza Pistone e coperchio di ricambio...

Diese Anleitung auch für:

Dial-air r21-04rgDial-air r21-03rgDial-air r21-06rgDial-air r21-02rg