Herunterladen Inhalt Inhalt Diese Seite drucken

Glossary; Introduction; Startup - AEG EM 50-2 Bedienungsanleitung

Eismelder
Vorschau ausblenden Andere Handbücher für EM 50-2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

usER Manual
Contents
Glossary ................................................................................... Page 6
Introduction .............................................................................. Page 6
Startup ...................................................................................... Page 6
Operation .................................................................................. Page 7
Main menu ................................................................................ Page 7
Display texts ............................................................................. Page 7

glossary

Zone 1, 2:
Independent heating zones in which ice and snow
can be melted.
Encoder button: Button which can be turned or pressed to easily
configure the settings.
EF 50-25 H:
Ground sensor for detecting moisture and
temperature.
F50-10 RH:
Gutter sensor for detecting moisture.
ATF 5:
Outdoor sensor for detecting temperature.
Afterrun:
The heat provided by the system, for a specified
length of time, after the moisture/temperature
signal has been eliminated by a heating cycle.

introduction

Type EM 50-2 is an electronic controller for fully automatic, eco-
nomical ice and snow melting on outdoor areas and in gutters. EM
50-2 detects both temperature and moisture and the heating system
will only be activated if a possibility of snow or ice is indicated by
both parameters.
An easily operated encoder button and backlit graphic display en-
sure quick and easy configuration and simple indication of tempera-
ture, status, etc.
EM 50-2 is suitable for controlling electric heating cables in 1 or 2
zones.

startup

When EM 50-2 is switched on for the first time,
sElECt sCalE:
Celsius or Fahrenheit must be selected. Turn the
CElCius
FaHREnHEit
encoder button until the required temperature
scale is highlighted. Then OK the selection by
pressing the encoder button.
SENSOR 1 is shown on the display, allowing
sEnsOR 1:
the type of sensor connected for input 1 to be
gROund sEnsOR
guttER sEnsOR
selected:
GROUND SENSOR
6
EM 50-2
English
© 2012 OJ Electronics A/S - ® OJ ist eine eingetragene Marke der OJ Electronics A/S
Application info ........................................................................ Page 7
Settings .................................................................................... Page 7
Offset calibration ...................................................................... Page 8
Factory settings ........................................................................ Page 9
Troubleshooting ........................................................................ Page 9
Illustrations ............................................................................. Page 10
GUTTER SENSOR + outdoor sensor
Then OK the selection by pressing the encoder
button.
SENSOR 2 is then shown on the display, al-
sEnsOR 2:
lowing the type of sensor connected for input 2
OFF
gROund sEnsOR
to be selected. If none sensor is connected for
guttER sEnsOR
input 2, OFF must be selected.
Select if outdoor sensor ATF 5 is connected
OutdOOR sEnsOR:
terminals 31-32.
OFF
atF
If none sensor is connected, OFF must be se-
lected. Press encoder button for OK.
Select the application type by turning the encod-
aPPliCatiOn:
er button and pressing OK.
ElECtRiC 1-ZOnE
ElECtRiC 2-ZOnE
ELECTRIC 1-ZONE : 1 zone electric heating
ElECtRiC 2-stEP
control/simple waterbased.
ELECTRIC 2-ZONE : 2 zones individual electrical
heating control/simple waterbased.
ELECTRIC 2-STEP : Advanced 2-stage electric
heating control (Y/Δ) for 1 zone. Reduces power
to 1/3 during the afterrun time. This applies only
to heating mats with 400 V. connection.
Select the appropriate option and press OK. The
system is now set up, and will begin operat-
ing fully automatically, in accordance with the
pre-configured standard program, see FACTORY
SETTINGS. Alternative settings can also be
made, see SETTINGS.
Status and afterheat data for zones 1 and 2 are
ZOnE 1 HEat OFF
ZOnE 2 HEat OFF
now shown on the display.
aFtERRun 1 0.00
aFtERRun 2 0.00
standBY
OFF
Developed by OJ Electronics A/S - www.ojelectronics.com

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis