Installation
Recommended mounting height from the floor level to the bottom of the hand dryer:
Adults 120 cm; wheelchair users, children 100 cm.
There must be a minimum clearance of 40 cm, in the direction of air discharge, from wall
shelves, wash-basins, etc!
Avoid reflecting surfaces within the detection range of the sensor lens!
When choosing the installation location, make sure that the safety distances in accordance with
the relevant national regulations are complied with!
With the special spanner (supplied in the small parts bag) turn the screws inside the casing cover
in the base of the unit all the way in (in clockwise direction).
Swing out cover at the bottom and remove in upward direction.
The packing box contains a drilling template with the dimensions of the mounting plate.
Mount the hand dryer on a vertical wall with the air outlet opening pointing downwards, bearing in
mind the mounting dimensions detailed below.
Dimensions in mm
Mark the location of the four mounting holes 235 mm x 197 mm (see illustration above).
Disconnect the relevant electrical circuit (shut off circuit breaker or remove fuse) before
continuing with the mounting work! When inserting the wall plugs, be careful of existing electrical
cables in the wall! Risk of electric shock!
However, special mounting materials may need to be used according to the construction of the
wall (e.g. lightweight partition walls). Seek specialist advice. Drill Ø 8 mm holes for the wall plugs
and insert the plugs.
Strip the power supply cable (for fixed wiring) and feed it through the opening in the back plate of
the device. Secure the back plate of the unit to the wall using the screws supplied.
6